Accuracy of blood pressure measurement and anthropometry among volunteer observers in a large community survey

被引:11
作者
Adams, C
Burke, V
Beilin, LJ
机构
[1] Univ Western Australia, Sch Dent, Crawley, WA 6009, Australia
[2] Univ Western Australia, Royal Perth Hosp, Dept Med, Perth, WA 6001, Australia
关键词
technical errors of measurement; blood pressure; anthropometry; quality control; volunteers; Busselton;
D O I
10.1016/S0895-4356(01)00492-9
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The Busselton Survey is a population survey that is held about every three years. In 1994-1995 a re-survey was held of all past participants and 8,502 attended. Financial constraints precluded employing staff for data collection for blood pressure and anthropometry, these therefore were collected by unpaid lay volunteers. Quality control by a health professional was critical to the assessment and maintenance of accuracy in these measurements. For blood pressure three readings were taken simultaneously by a quality control person and die volunteer using a dual stethoscope. Duplicate anthropometric measurements were taken by a criterion anthropometrist and the volunteer. Inter and intra-observer technical errors of measurement (TEM) were calculated. Sixty-two volunteers were trained to take BP measurements; of these, 38 collected data, and 63 were trained in anthropometry; of these, 30 were suitable as measurers. Training was conducted on a group and individual basis by the quality assurance person for the study both in the Perth metropolitan area and rural Busselton. The TEM for SBP was 1.6 mm Hg (SD 1.0 min Hg) and 1.5 min fig (SD 0.8) for DBP. For skin-folds intra-observer TEM ranged front 0.6 mm to 1.0 mm. Between-observer TEM ranged from 2.1 min to 5.4 mm. For limb and waist circumferences, intra-observer TEM ranged from 0.3 cm to 1.6 cm. Between-observer TEM for circumferences ranged from 0.5 cm to 1.9 cm. Unpaid volunteer measurers can, if carefully trained and supervised, provide acceptable blood pressure data and anthropometry in large population surveys. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:338 / 344
页数:7
相关论文
共 26 条
[1]  
*AM HEART ASS, 1980, CIRCULATION, V62, pA1146
[2]  
[Anonymous], BLOOD PRESSURE SOUND
[4]  
BRANSON RS, 1982, HUM BIOL, V54, P137
[5]  
CAMPBELL N, 1994, REV CAN SANTE PUBL, V85, pS18
[6]   THE HYPERTENSION PREVENTION TRIAL - ASSESSMENT OF THE QUALITY OF BLOOD-PRESSURE MEASUREMENTS [J].
CANNER, PL ;
BORHANI, NO ;
OBERMAN, A ;
CUTLER, J ;
PRINEAS, RJ ;
LANGFORD, H ;
HOOPER, FJ .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 134 (04) :379-392
[7]   TRAINING AND CERTIFICATION OF BLOOD-PRESSURE OBSERVERS [J].
CURB, JD ;
LABARTHE, DR ;
COOPER, SP ;
CUTTER, GR ;
HAWKINS, CM .
HYPERTENSION, 1983, 5 (04) :610-614
[8]   ASSESSMENT OF THE RELIABILITY OF PHYSICAL MEASURES [J].
ENGSTROM, JL .
RESEARCH IN NURSING & HEALTH, 1988, 11 (06) :383-389
[9]   MEASURED DIFFERENCES BETWEEN 4TH AND 5TH PHASE DIASTOLIC BLOOD PRESSURES IN 4885 ADULTS - IMPLICATIONS FOR BLOOD-PRESSURE SURVEYS [J].
FOLSOM, AR ;
PRINEAS, RJ ;
JACOBS, DR ;
LUEPKER, RV ;
GILLUM, RF .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1984, 13 (04) :436-441
[10]   MEASUREMENT ERROR AND RELIABILITY IN 4 PEDIATRIC CROSS-SECTIONAL SURVEYS OF CARDIOVASCULAR-DISEASE RISK FACTOR VARIABLES - THE BOGALUSA HEART-STUDY [J].
FOSTER, TA ;
BERENSON, GS .
JOURNAL OF CHRONIC DISEASES, 1987, 40 (01) :13-21