Probability-based validation of protein identifications using a modified SEQUEST algorithm

被引:302
作者
MacCoss, MJ
Wu, CC
Yates, JR [1 ]
机构
[1] Scripps Res Inst, Dept Cell Biol, La Jolla, CA 92037 USA
[2] Torrey Mesa Res Inst, Dept Proteom & Metabolom, San Diego, CA 92121 USA
关键词
D O I
10.1021/ac025826t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Database-searching algorithms compatible with shotgun proteomics match a peptide tandem mass spectrum to a predicted mass spectrum for an amino acid sequence within a database. SEQUEST is one of the most common software algorithms used for the analysis of peptide tandem mass spectra by using across-correlation (XCorr) scoring routine to match tandem mass spectra to model spectra derived from peptide sequences.. To assess a match, SEQUEST uses the difference between the first- and second-ranked sequences (DeltaCn). This, value is dependent on the database size, search parameters, and sequence homologies. In this report, we demonstrate the use of a scoring routine (SEQUEST-NORM) that normalizes XCorr values to be independent of peptide size and the database used to perform the search. This new scoring routine is used to objectively calculate the percent confidence of protein identifications and posttranslational modifications based solely on the XCorr value.
引用
收藏
页码:5593 / 5599
页数:7
相关论文
共 17 条
[1]   CHARGE PROMOTION OF LOW-ENERGY FRAGMENTATIONS OF PEPTIDE IONS [J].
BURLET, O ;
ORKISZEWSKI, RS ;
BALLARD, KD ;
GASKELL, SJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :658-662
[2]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[3]   Automated identification of amino acid sequence variations in proteins by HPLC/microspray tandem mass spectrometry [J].
Gatlin, CL ;
Eng, JK ;
Cross, ST ;
Detter, JC ;
Yates, JR .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :757-763
[4]   STRUCTURAL-ANALYSIS OF PROTEINS BY CAPILLARY HPLC ELECTROSPRAY TANDEM MASS-SPECTROMETRY [J].
GRIFFIN, PR ;
COFFMAN, JA ;
HOOD, LE ;
YATES, JR .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 111 :131-149
[5]   LC/MS AND LC/MS/MS DETERMINATION OF PROTEIN TRYPTIC DIGESTS [J].
HUANG, EC ;
HENION, JD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (02) :158-165
[6]   PROTEIN SEQUENCING BY TANDEM MASS-SPECTROMETRY [J].
HUNT, DF ;
YATES, JR ;
SHABANOWITZ, J ;
WINSTON, S ;
HAUER, CR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (17) :6233-6237
[7]   Direct analysis of protein complexes using mass spectrometry [J].
Link, AJ ;
Eng, J ;
Schieltz, DM ;
Carmack, E ;
Mize, GJ ;
Morris, DR ;
Garvik, BM ;
Yates, JR .
NATURE BIOTECHNOLOGY, 1999, 17 (07) :676-682
[8]   Shotgun identification of protein modifications from protein complexes and lens tissue [J].
MacCoss, MJ ;
McDonald, WH ;
Saraf, A ;
Sadygov, R ;
Clark, JM ;
Tasto, JJ ;
Gould, KL ;
Wolters, D ;
Washburn, M ;
Weiss, A ;
Clark, JI ;
Yates, JR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (12) :7900-7905
[9]   Code developments to improve the efficiency of automated MS/MS spectra interpretation [J].
Sadygov, RG ;
Eng, J ;
Durr, E ;
Saraf, A ;
McDonald, H ;
MacCoss, MJ ;
Yates, JR .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (03) :211-215
[10]   SMOOTHING + DIFFERENTIATION OF DATA BY SIMPLIFIED LEAST SQUARES PROCEDURES [J].