Robust design of countercurrent adsorption separation processes .4. Desorbent in the feed

被引:36
作者
Mazzotti, M
Storti, G
Morbidelli, M
机构
[1] ETH ZENTRUM,TECH CHEM LAB,CH-8092 ZURICH,SWITZERLAND
[2] POLITECN MILAN,DIPARTIMENTO CHIM,I-20131 MILAN,ITALY
[3] UNIV CAGLIARI,DIPARTIMENTO INGN CHIM & MAT,I-09123 CAGLIARI,ITALY
关键词
D O I
10.1002/aic.690430109
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In many instances of practical interest, countercurrent adsorption separations operate on feed streams containing not only the components to be separated but also some desorbent. Criteria for the optimal and robust design and operation of these units are developed by extending previous treatments developed for desorbent-free feedstreams. The effect of the presence of some desorbent (weak, intermediate, or strong) on the location and robustness of the region of complete separation in the operating parameter space is discussed.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 18 条
[1]  
BACIOCCHI R, 1996, FUNDAMENTALS ADSORPT
[2]   COMPLETE DESIGN OF A SIMULATED MOVING-BED [J].
CHARTON, F ;
NICOUD, RM .
JOURNAL OF CHROMATOGRAPHY A, 1995, 702 (1-2) :97-112
[3]   COMPARATIVE-STUDY OF FLOW SCHEMES FOR A SIMULATED COUNTERCURRENT ADSORPTION SEPARATION PROCESS [J].
CHING, CB ;
CHU, KH ;
HIDAJAT, K ;
UDDIN, MS .
AICHE JOURNAL, 1992, 38 (11) :1744-1750
[4]   PREPARATIVE RESOLUTION OF PRAZIQUANTEL ENANTIOMERS BY SIMULATED COUNTERCURRENT CHROMATOGRAPHY [J].
CHING, CB ;
LIM, BG ;
LEE, EJD ;
NG, SC .
JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02) :215-219
[5]   AN EXPERIMENTAL-STUDY OF A SIMULATED COUNTERCURRENT ADSORPTION SYSTEM .1. ISOTHERMAL STEADY-STATE OPERATION [J].
CHING, CB ;
RUTHVEN, DM .
CHEMICAL ENGINEERING SCIENCE, 1985, 40 (06) :877-885
[6]  
GANETSOS G, 1993, PREPARATIVE PRODUCTI
[7]  
Helfferich F G, 1970, MULTICOMPONENT CHROM
[8]   THE H-TRANSFORMATIONS AND DELTA-TRANSFORMATIONS IN MULTICOMPONENT FIXED-BED ION-EXCHANGE AND ADSORPTION - EQUIVALENT MATHEMATICS, DIFFERENT SCOPE [J].
HELFFERICH, FG .
CHEMICAL ENGINEERING SCIENCE, 1991, 46 (12) :3320-3323
[9]   ENANTIOSEPARATION OF A CHIRAL EPOXIDE BY SIMULATED MOVING-BED CHROMATOGRAPHY USING CHIRALCEL-OD [J].
KUSTERS, E ;
GERBER, G ;
ANTIA, FD .
CHROMATOGRAPHIA, 1995, 40 (7-8) :387-393
[10]   Robust design of countercurrent adsorption separation .3. Nonstoichiometric systems [J].
Mazzotti, M ;
Storti, G ;
Morbidelli, M .
AICHE JOURNAL, 1996, 42 (10) :2784-2796