Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients - An evaluation from the Rapamycin-Eluting Stent evaluated at Rotterdam Cardiology Hospital (RESEARCH) study

被引:247
作者
Lemos, PA
Hoye, A
Goedhart, D
Arampatzis, CA
Saia, F
van der Giessen, WJ
McFadden, E
Sianos, G
Smits, PC
Hofma, SH
de Feyter, PJ
van Domburg, RT
Serruys, PW
机构
[1] Erasmus Med Ctr Rotterdam, Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus Med Ctr Rotterdam, Cardialysis BV, Dept Stat, NL-3015 GD Rotterdam, Netherlands
关键词
stents; angioplasty; revascularization; restenosis;
D O I
10.1161/01.CIR.0000121358.26097.06
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - The factors associated with the occurrence of restenosis after sirolimus-eluting stent (SES) implantation in complex cases are currently unknown. Methods and Results - A cohort of consecutive complex patients treated with SES implantation was selected according to the following criteria: ( 1) treatment of acute myocardial infarction, ( 2) treatment of in-stent restenosis, ( 3) 2.25-mm diameter SES, ( 4) left main coronary stenting, ( 5) chronic total occlusion, ( 6) stented segment > 36 mm, and ( 7) bifurcation stenting. The present study population was composed of 238 patients ( 441 lesions) for whom 6-month angiographic follow-up data were obtained (70% of eligible patients). Significant clinical, angiographic, and procedural predictors of post-SES restenosis were evaluated. Binary in-segment restenosis was diagnosed in 7.9% of lesions (6.3% in-stent, 0.9% at the proximal edge, 0.7% at the distal edge). The following characteristics were identified as independent multivariate predictors: treatment of in-stent restenosis ( OR 4.16, 95% CI 1.63 to 11.01; P < 0.01), ostial location (OR 4.84, 95% CI 1.81 to 12.07; P < 0.01), diabetes ( OR 2.63, 95% CI 1.14 to 6.31; P = 0.02), total stented length ( per 10-mm increase; OR 1.42, 95% CI 1.21 to 1.68; P < 0.01), reference diameter ( per 1.0-mm increase; OR 0.46, 95% CI 0.24 to 0.87; P = 0.03), and left anterior descending artery ( OR 0.30, 95% CI 0.10 to 0.69; P < 0.01). Conclusions - Angiographic restenosis after SES implantation in complex patients is an infrequent event, occurring mainly in association with lesion-based characteristics and diabetes mellitus.
引用
收藏
页码:1366 / 1370
页数:5
相关论文
共 23 条
[1]   Predictors of restenosis after coronary stent implantation [J].
Bauters, C ;
Hubert, E ;
Prat, A ;
Bougrimi, K ;
Van Belle, E ;
McFadden, EP ;
Amouyel, P ;
Lablanche, JM ;
Bertrand, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) :1291-1298
[2]   In-stent restenosis in small coronary arteries - Impact of strut thickness [J].
Briguori, C ;
Sarais, C ;
Pagnotta, P ;
Liistro, F ;
Montorfano, M ;
Chieffo, A ;
Sgura, F ;
Corvaja, N ;
Albiero, R ;
Stankovic, G ;
Toutoutzas, C ;
Bonizzoni, E ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :403-409
[3]   Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography [J].
de Feyter, PJ ;
Kay, P ;
Disco, C ;
Serruys, PW .
CIRCULATION, 1999, 100 (17) :1777-1783
[4]   Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions [J].
Degertekin, M ;
Lemos, PA ;
Lee, CH ;
Tanabe, K ;
Sousa, JE ;
Abizaid, A ;
Regar, E ;
Sianos, G ;
van der Giessen, WJ ;
de Feyter, PJ ;
Wuelfert, E ;
Popma, JJ ;
Serruys, PW .
EUROPEAN HEART JOURNAL, 2004, 25 (01) :32-38
[5]   Sirolimus-eluting stent for treatment of complex in-stent restenosis - The first clinical experience [J].
Degertekin, M ;
Regar, E ;
Tanabe, K ;
Smits, PC ;
van der Giessen, WJ ;
Carlier, SG ;
de Feyter, P ;
Vos, J ;
Foley, DP ;
Ligthart, JMR ;
Popma, JJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (02) :184-189
[6]   Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Pache, J ;
Wehinger, A ;
Hadamitzky, M ;
Dirschinger, J ;
Neumann, FJ ;
Schömig, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1866-1873
[7]   Vessel size and long-term outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Neumann, FJ ;
Hadamitzky, M ;
Dirschinger, J ;
Schömig, A .
CIRCULATION, 1998, 98 (18) :1875-1880
[8]  
Harrell FE, 1996, STAT MED, V15, P361, DOI 10.1002/(SICI)1097-0258(19960229)15:4<361::AID-SIM168>3.0.CO
[9]  
2-4
[10]   Predictive factors for early cardiac events and angiographic restenosis after coronary stent placement in small coronary arteries [J].
Hausleiter, J ;
Kastrati, A ;
Mehilli, J ;
Schühlen, H ;
Pache, J ;
Dotzer, F ;
Dirschinger, J ;
Schömig, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (05) :882-889