A systematic review of stroke recognition instruments in hospital and prehospital settings

被引:59
作者
Rudd, Matthew [1 ,2 ]
Buck, Deborah [1 ]
Ford, Gary A. [3 ]
Price, Christopher I. [1 ,2 ]
机构
[1] Newcastle Univ, Inst Neurosci, Stroke Res Grp, 3-4 Claremont Terrace, Newcastle Upon Tyne NE2 4AE, Tyne & Wear, England
[2] Wansbeck Gen Hosp, Northumbria Healthcare NHS Fdn Trust, Ashington, Northd, England
[3] Univ Oxford, Div Med Sci, Oxford, England
关键词
DIAGNOSTIC-ACCURACY; EMERGENCY; IDENTIFICATION; VALIDATION; SCALE; CARE; SENSITIVITY; OUTCOMES; SCORES; TOOL;
D O I
10.1136/emermed-2015-205197
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background We undertook a systematic review of all published stroke identification instruments to describe their performance characteristics when used prospectively in any clinical setting. Methods A search strategy was applied to Medline and Embase for material published prior to 10 August 2015. Two authors independently screened titles, and abstracts as necessary. Data including clinical setting, reported sensitivity, specificity, positive predictive value, negative predictive value were extracted independently by two reviewers. Results 5622 references were screened by title and or abstract. 18 papers and 3 conference abstracts were included after full text review. 7 instruments were identified; Face Arm Speech Test (FAST), Recognition of Stroke in the Emergency Room (ROSIER), Los Angeles Prehospital Stroke Screen (LAPSS), Melbourne Ambulance Stroke Scale (MASS), Ontario Prehospital Stroke Screening tool (OPSS), Medic Prehospital Assessment for Code Stroke (MedPACS) and Cincinnati Prehospital Stroke Scale (CPSS). Cohorts varied between 50 and 1225 individuals, with 17.5% to 92% subsequently receiving a stroke diagnosis. Sensitivity and specificity for the same instrument varied across clinical settings. Studies varied in terms of quality, scoring 1331/36 points using modified Standards for the Reporting of Diagnostic accuracy studies checklist. There was considerable variation in the detail reported about patient demographics, characteristics of false-negative patients and service context. Prevalence of instrument detectable stroke varied between cohorts and over time. CPSS and the similar FAST test generally report the highest level of sensitivity, with more complex instruments such as LAPSS reporting higher specificity at the cost of lower detection rates. Conclusions Available data do not allow a strong recommendation to be made about the superiority of a stroke recognition instrument. Choice of instrument depends on intended purpose, and the consequences of a false-negative or false-positive result.
引用
收藏
页码:818 / 822
页数:5
相关论文
共 35 条
[1]   Guidelines for the early management of adults with ischemic stroke - A guideline from the American Heart Association/American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the atherosclerotic peripheral vascular disease and quality of care outcomes in research interdisciplinary working groups [J].
Adams, Harold P., Jr. ;
del Zoppo, Gregory ;
Alberts, Mark J. ;
Bhatt, Deepak L. ;
Brass, Lawrence ;
Furlan, Anthony ;
Grubb, Robert L. ;
Higashida, Randall T. ;
Jauch, Edward C. ;
Kidwell, Chelsea ;
Lyden, Patrick D. ;
Morgenstern, Lewis B. ;
Qureshi, Adnan I. ;
Rosenwasser, Robert H. ;
Scott, Phillip A. ;
Wijdicks, Eelco F. M. .
STROKE, 2007, 38 (05) :1655-1711
[2]   Understanding diagnostic tests 1: sensitivity, specificity and predictive values [J].
Akobeng, Anthony K. .
ACTA PAEDIATRICA, 2007, 96 (03) :338-341
[3]   Out-of-Hospital Stroke Screen Accuracy in a State With an Emergency Medical Services Protocol for Routing Patients to Acute Stroke Centers [J].
Asimos, Andrew W. ;
Ward, Shana ;
Brice, Jane H. ;
Rosamond, Wayne D. ;
Goldstein, Larry B. ;
Studnek, Jonathan .
ANNALS OF EMERGENCY MEDICINE, 2014, 64 (05) :509-515
[4]   Towards complete and,accurate reporting of studies of diagnostic accuracy: the STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCE .
BRITISH MEDICAL JOURNAL, 2003, 326 (7379) :41-44
[5]   Prehospital stroke scales in urban environments A systematic review [J].
Brandler, Ethan S. ;
Sharma, Mohit ;
Sinert, Richard H. ;
Levine, Steven R. .
NEUROLOGY, 2014, 82 (24) :2241-2249
[6]   Paramedic Diagnosis of Stroke Examining Long-Term Use of the Melbourne Ambulance Stroke Screen (MASS) in the Field [J].
Bray, Janet E. ;
Coughlan, Kelly ;
Barger, Bill ;
Bladin, Chris .
STROKE, 2010, 41 (07) :1363-1366
[7]   Paramedic identification of stroke: Community validation of the Melbourne Ambulance Stroke Screen [J].
Bray, JE ;
Martin, J ;
Cooper, G ;
Barger, B ;
Bernard, S ;
Bladin, C .
CEREBROVASCULAR DISEASES, 2005, 20 (01) :28-33
[8]  
Chen SR, 2013, PLOS ONE, V8, DOI [10.1371/journal.pone.0056380, 10.1371/journal.pone.0053662]
[9]   Predictive Value of the Ontario Prehospital Stroke Screening Tool for the Identification of Patients with Acute Stroke [J].
Chenkin, Jordan ;
Gladstone, David J. ;
Verbeek, P. Richard ;
Lindsay, Patrice ;
Fang, Jiming ;
Black, Sandra E. ;
Morrison, Laurie .
PREHOSPITAL EMERGENCY CARE, 2009, 13 (02) :153-159
[10]  
Doh H, 2014, INTENSIVE CARE ME S1, V40