Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Reproducibility, comparison of 2 agents, and distribution of microemboli

被引:84
作者
Droste, DW
Reisener, M
Kemény, V
Dittrich, R
Schulte-Altedorneburg, G
Stypmann, J
Wichter, T
Ringelstein, EB
机构
[1] Univ Munster, Dept Neurol, D-4400 Munster, Germany
[2] Univ Munster, Dept Cardiol & Angiol, D-4400 Munster, Germany
[3] Univ Munster, Inst Arteriosclerosis Res, D-4400 Munster, Germany
关键词
cerebral embolism; cerebrovascular disorders; foramen ovale; patent; ultrasonography;
D O I
10.1161/01.STR.30.5.1014
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Furthermore, we assessed the side distribution of thus provoked artificial cardiac emboli. Methods-Fifty-four patients were investigated by TEE and by bilateral TCD of the middle cerebral artery, The following protocol was performed twice: injection of 9 mL of agitated saline without Valsalva maneuver, injection of 9 mt of agitated saline with Valsalva maneuver, injection of 5 mL of a commercial galactose-based contrast agent without Valsalva maneuver, and injection of 5 mt of the galactose-based contrast agent with Valsalva maneuver. Results-In 18 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt positive). Twenty-nine patients were negative in both investigations, 1 was positive on TEE and negative on TCD, and 6 patients were only positive on TCD. Both bilateral and repeated recordings increased the sensitivity of contrast TCD, There was a symmetrical distribution of microembolic signals in the right and left middle cerebral artery. Conclusions-TCD performed twice and with the use of saline or a galactose-based contrast agent is a sensitive method in the identification of cardiac right-to-left shunts also identified by TEE, The cardiac microemboli in this study did not show any side preference for one of the middle cerebral arteries.
引用
收藏
页码:1014 / 1018
页数:5
相关论文
共 41 条
[1]  
[Anonymous], 1997, Diabetes Care, V20 Suppl 1, pS1
[2]   VALIDATION OF TRANSCRANIAL DOPPLER SONOGRAPHY IN THE ASSESSMENT OF PATENT FORAMEN OVALE [J].
ANZOLA, GP ;
RENALDINI, E ;
MAGONI, M ;
COSTA, A ;
COBELLI, M ;
GUINDANI, M .
CEREBROVASCULAR DISEASES, 1995, 5 (03) :194-198
[3]   COMPARISON OF TRANSESOPHAGEAL AND TRANSTHORACIC ECHOCARDIOGRAPHY WITH CONTRAST AND COLOR-FLOW DOPPLER IN THE DETECTION OF PATENT FORAMEN OVALE [J].
BELKIN, RN ;
POLLACK, BD ;
RUGGIERO, ML ;
ALAS, LL ;
TATINI, U .
AMERICAN HEART JOURNAL, 1994, 128 (03) :520-525
[4]   Stroke recurrence in patients with patent foramen ovale: The Lausanne Study [J].
Bogousslavsky, J ;
Garazi, S ;
Jeanrenaud, X ;
Aebischer, N ;
VanMelle, G .
NEUROLOGY, 1996, 46 (05) :1301-1305
[5]   LUNG AS A FILTER FOR MICROBUBBLES [J].
BUTLER, BD ;
HILLS, BA .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (03) :537-543
[6]   ATRIAL SEPTAL ANEURYSM AND PATENT FORAMEN OVALE AS RISK-FACTORS FOR CRYPTOGENIC STROKE IN PATIENTS LESS-THAN 55 YEARS OF AGE - A STUDY USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CABANES, L ;
MAS, JL ;
COHEN, A ;
AMARENCO, P ;
CABANES, PA ;
OUBARY, P ;
CHEDRU, F ;
GUERIN, F ;
BOUSSER, MG ;
DERECONDO, J .
STROKE, 1993, 24 (12) :1865-1873
[7]   A PROSPECTIVE-STUDY OF CEREBRAL-ISCHEMIA IN THE YOUNG - ANALYSIS OF PATHOGENIC DETERMINANTS [J].
CAROLEI, A ;
MARINI, C ;
FERRANTI, E ;
FRONTONI, M ;
PRENCIPE, M ;
FIESCHI, C ;
TOTARO, R ;
LANDI, G ;
BINDA, A ;
DEZANCHE, L ;
PARMA, M ;
SCODITTI, U ;
ZANETTE, EM ;
INZITARI, D ;
NENCINI, P ;
GANDOLFO, C ;
MORETTI, C ;
FINOCCHI, C ;
LOEB, CW .
STROKE, 1993, 24 (03) :362-367
[8]   DETECTION OF PATENT FORAMEN OVALE BY CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CHEN, WJ ;
KUAN, PL ;
LIEN, WP ;
LIN, FY .
CHEST, 1992, 101 (06) :1515-1520
[9]   Prognosis after stroke followed by surgical closure of patent foramen ovale: A prospective follow-up study with brain MRI and simultaneous transesophageal and transcranial Doppler ultrasound [J].
Devuyst, G ;
Bogousslavsky, J ;
Ruchat, P ;
Jeanrenaud, X ;
Despland, AP ;
Regli, F ;
Aebischer, N ;
Karpuz, HM ;
Castillo, V ;
Guffi, M ;
Sadeghi, H .
NEUROLOGY, 1996, 47 (05) :1162-1166
[10]   PATENT FORAMEN OVALE AS A RISK FACTOR FOR CRYPTOGENIC STROKE [J].
DITULLIO, M ;
SACCO, RL ;
GOPAL, A ;
MOHR, JP ;
HOMMA, S .
ANNALS OF INTERNAL MEDICINE, 1992, 117 (06) :461-465