A comparison of magnetization prepared 3D gradient-echo (MP-RAGE) sequences for imaging of intracranial lesions

被引:25
作者
Bluml, S [1 ]
Schad, LR [1 ]
Scharf, J [1 ]
Wenz, F [1 ]
Knopp, MV [1 ]
Lorenz, WJ [1 ]
机构
[1] DEUTSCH KREBSFORSCHUNGSZENTRUM,FORSCH SCHWERPUNKT RADIOL,D-69009 HEIDELBERG,GERMANY
关键词
magnetic resonance imaging; magnetization prepared 3D gradient-echo techniques; brain lesions;
D O I
10.1016/0730-725X(95)02095-B
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In a pilot study including 64 patients with different types of brain tumors we investigated four types of MP-RAGE sequences, The sequences differ in the length of the recovery period and the data acquisition mode (sequential vs, centric phase-encoding). The sequence with sequential encoding and a short recovery period provided images that reached the quality and reliability of spin-echo images, The other MP-RAGE sequences failed in providing equivalent information. In particular, a considerable number of small lesions identified in spin-echo images were not detected in MP-RAGE images, The impact of the evolving magnetization on the point spread function was analyzed by performing simulation calculations, It was found that lesions with short T-1 times are rendered with low spatial resolution when sequence parameters are not set appropriately, The low overall quality of images obtained by sequences applying centric encoding may be explained by eddy current effects as reported in other recently published studies.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 19 条
[1]   MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN [J].
BRANTZAWADZKI, M ;
GILLAN, GD ;
NITZ, WR .
RADIOLOGY, 1992, 182 (03) :769-775
[2]  
CHIEN D, 1991, Magnetic Resonance Quarterly, V7, P31
[3]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[4]   MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING [J].
DELANGE, EE ;
MUGLER, JP ;
BERTOLINA, JA ;
GAY, SB ;
JANUS, CL ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IMAGING, 1991, 9 (04) :469-476
[5]   OPTIMIZATION OF PARAMETER VALUES FOR COMPLEX PULSE SEQUENCES BY SIMULATED ANNEALING - APPLICATION TO 3D MP-RAGE IMAGING OF THE BRAIN [J].
EPSTEIN, FH ;
MUGLER, JP ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) :164-177
[6]   INVERSION IN THE STEADY-STATE - CONTRAST OPTIMIZATION AND REDUCED IMAGING TIME WITH FAST 3-DIMENSIONAL INVERSION-RECOVERY - PREPARED GRE PULSE SEQUENCES [J].
FOO, TKF ;
SAWYER, AM ;
FAULKNER, WH ;
MILLS, DG .
RADIOLOGY, 1994, 191 (01) :85-90
[7]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[8]   DIFFUSION AND FIELD-GRADIENT EFFECTS IN NMR FOURIER SPECTROSCOPY [J].
KAISER, R ;
BARTHOLDI, E ;
ERNST, RR .
JOURNAL OF CHEMICAL PHYSICS, 1974, 60 (08) :2966-2979
[9]   SHAPING THE SIGNAL RESPONSE DURING THE APPROACH TO STEADY-STATE IN 3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING USING VARIABLE FLIP ANGLES [J].
MUGLER, JP ;
EPSTEIN, FH ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :165-185
[10]   3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING (3DMP-RAGE) [J].
MUGLER, JP ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (01) :152-157