A comprehensive two-dimensional retention time alignment algorithm to enhance chemometric analysis of comprehensive two-dimensional separation data

被引:109
作者
Pierce, KM
Wood, LF
Wright, BW
Synovec, RE
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac0511142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comprehensive two-dimensional (21)) retention time alignment algorithm was developed using a novel indexing scheme. The algorithm is termed comprehensive because it functions to correct the entire chromatogram in both dimensions and it preserves the separation information in both dimensions. Although the algorithm is demonstrated by correcting comprehensive two-dimensional gas chromatography (GC x GC) data, the algorithm is designed to correct shifting in all forms of 2D separations, such as LC x LC, LC x CE, CE x CE, and LC x GC. This 2D alignment algorithm was applied to three different data sets composed of replicate GC x GC separations of (1) three 22-component control mixtures, (2) three gasoline samples, and (3) three diesel samples. The three data sets were collected using slightly different temperature or pressure programs to engender significant retention time shifting in the raw data and then demonstrate subsequent corrections of that shifting upon comprehensive 2D alignment of the data sets. Thirty 12-min GC x GC separations from three 22-component control mixtures were used to evaluate the 2D alignment performance (10 runs/mixture). The average standard deviation of first column retention time improved 5-fold from 0.020 min (before alignment) to 0.004 min (after alignment). Concurrently, the average standard deviation of second column retention time improved 4-fold from 3.5 ms (before alignment) to 0.8 ms (after alignment). Alignment of the 30 control mixture chromatograms took 20 min. The quantitative integrity of the GC x GC data following 2D alignment was also investigated. The mean integrated signal was determined for all components in the three 22-component mixtures for all 30 replicates. The average percent difference in the integrated signal for each component before and after alignment was 2.6%. Singular value decomposition (SVD) was applied to the 22-component control mixture data before and after alignment to show the restoration of trilinearity to the data, since trilinearity benefits chemometric analysis. By applying comprehensive 2D retention time alignment to all three data sets (control mixtures, gasoline samples, and diesel samples), classification by principal component analysis (PCA) substantially improved, resulting in 100% accurate scores clustering.
引用
收藏
页码:7735 / 7743
页数:9
相关论文
共 42 条
[1]   CORRELATION OF QUANTITATIVE-ANALYSIS PRECISION TO RETENTION TIME PRECISION AND CHROMATOGRAPHIC RESOLUTION FOR RAPID, SHORT COLUMN ANALYSIS [J].
BAHOWICK, TJ ;
SYNOVEC, RE .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :631-640
[2]   Mathematical alignment of wavelength-shifted optical spectra for qualitative and quantitative analysis [J].
Booksh, KS ;
Stellman, CM ;
Bell, WC ;
Myrick, ML .
APPLIED SPECTROSCOPY, 1996, 50 (02) :139-147
[3]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[4]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[5]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[6]   Separation and identification of compounds in Rhizoma chuanxiong by comprehensive two-dimensional liquid chromatography coupled to mass spectrometry [J].
Chen, XG ;
Kong, L ;
Su, XY ;
Fu, HJ ;
Ni, JY ;
Zhao, RH ;
Zou, HF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1040 (02) :169-178
[7]   Translation and scale invariants of Legendre moments [J].
Chong, CW ;
Raveendran, P ;
Mukundan, R .
PATTERN RECOGNITION, 2004, 37 (01) :119-129
[8]   Chromatographic preprocessing of GC-MS data for analysis of complex chemical mixtures [J].
Christensen, JH ;
Mortensen, J ;
Hansen, AB ;
Andersen, O .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (01) :113-123
[9]   Comparison between the direct trilinear decomposition and the multivariate curve resolution-alternating least squares methods for the resolution of three-way data sets [J].
de Juan, A ;
Rutan, SC ;
Tauler, R ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 40 (01) :19-32
[10]   Parametric time warping [J].
Eilers, PHC .