Non-exhaustive double effort test is reliable and estimates the first ventilatory threshold intensity in running exercise

被引:2
作者
Maia Forte, Lucas Dantas [1 ]
Manchado-Gobatto, Fulvia Barros [1 ]
Matheus Rodrigues, Roberta Cunha [2 ]
Gallani, Maria Ceclia [3 ]
Gobatto, Claudio Alexandre [1 ]
机构
[1] Univ Estadual Campinas, Sch Appl Sci, BR-13484350 Sao Paulo, Brazil
[2] Univ Estadual Campinas, Sch Nursing, BR-13083970 Sao Paulo, Brazil
[3] Laval Univ, Fac Nursing, Quebec City, PQ G1V 0A6, Canada
基金
巴西圣保罗研究基金会;
关键词
Aerobic exercise; Anaerobic threshold; Maximal lactate steady state; Non-exhaustive protocol; Training prescription; Ventilatory threshold; HEART-RATE-VARIABILITY; LACTATE STEADY-STATE; AEROBIC CAPACITY DETERMINATION; ANAEROBIC THRESHOLD; BLOOD LACTATE; RELIABILITY; VALIDATION; VALIDITY; PROTOCOL;
D O I
10.1016/j.jshs.2017.02.001
中图分类号
F [经济];
学科分类号
020101 [政治经济学];
摘要
Purpose: The present study aimed to investigate the reliability of the non-exhaustive double effort (NEDE) test in running exercise and its associations with the ventilatory thresholds (VT1 and VT2) and the maximal lactate steady state (MLSS). Methods: Ten healthy male adults (age: 23 4 years, height: 176.6 +/- 6.4 cm, body mass: 76.6 +/- 10.7 kg) performed 4 procedures: (1) a ramp test for VT1 and VT2 determinations measured by ratio of expired ventilation to O-2 uptake (VENO2) and expired ventilation to CO2 output (VENCO2) equivalents, respectively; (2) the NEDE test measured by blood lactate concentration (NEDELAC) and heart rate responses (NEDEHR); (3) a retest of NEDE for reliability analysis; and (4) continuous efforts to determine the MLSS intensity. The NEDE test consisted of 4 sessions at different running intensities. Each session was characterized by double efforts at the same running velocity (El and E2, 180 s), separated by a passive recovery period (90 s rest). LAC and HR values after El and E2 (in 4 sessions) were used to estimate the intensity equivalent to "null delta" by linear fit. This parameter represents, theoretically, the intensity equivalent to maximal aerobic capacity. Results: The intraclass correlation coefficient indicated significant reliability for NEDELAC (0.93) and NEDEHR (0.79) (both p < 0.05). There were significant correlations, no differences, and strong agreement with the intensities predicted by NEDELAC (10.1 1.9 km/h) and NEDEHR (9.8 +/- 2.0 km/h) to VT1 (10.2 +/- 1.1 km/h). In addition, despite significantly lower MLSS intensity (12.2 +/- 1.2 km/h), NEDELAC and NEDEHR intensities were highly correlated with this parameter (0.90 and 0.88, respectively). Conclusion: The NEDE test applied to running exercise is reliable and estimates the VT1 intensity. Additionally, NEDE intensities were lower but still correlated with VT2 and MLSS. (C) 2018 Published by Elsevier B.V. on behalf of Shanghai University of Sport.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 34 条
[1]   What is the most effective exercise protocol to improve cardiovascular fitness in overweight and obese subjects? [J].
Aparecida Castro, Eliane ;
Belen Peinado, Ana ;
Jose Benito, Pedro ;
Galindo, Mercedes ;
Gonzalez-Gross, Marcela ;
Cupeiro, Rocio .
JOURNAL OF SPORT AND HEALTH SCIENCE, 2017, 6 (04) :454-461
[2]   Exercise intensity optimization for men with high cardiorespiratory fitness [J].
Azevedo, Luciene F. ;
Perlingeiro, Patricia S. ;
Brum, Patricia C. ;
Braga, Ana Maria W. ;
Negrao, Carlos E. ;
de Matos, Luciana D. N. J. .
JOURNAL OF SPORTS SCIENCES, 2011, 29 (06) :555-561
[3]   Effect of test interruptions on blood lactate during constant workload [J].
Beneke, R ;
Hütler, M ;
Von Duvillard, SP ;
Sellens, M ;
Leithäuser, RM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (09) :1626-1630
[4]   A METHOD FOR DETERMINING THE MAXIMAL STEADY-STATE OF BLOOD LACTATE CONCENTRATION FROM 2 LEVELS OF SUBMAXIMAL EXERCISE [J].
BILLAT, V ;
DALMAY, F ;
ANTONINI, MT ;
CHASSAIN, AP .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 69 (03) :196-202
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
CHASSAIN A-P, 1986, Science and Sports, V1, P41, DOI 10.1016/S0765-1597(86)80073-9
[7]  
Manchado FD, 2006, APPL PHYSIOL NUTR ME, V31, P731, DOI [10.1139/H06-079, 10.1139/h06-079]
[8]   Maximal lactate steady state, respiratory compensation threshold and critical power [J].
Dekerle, J ;
Baron, B ;
Dupont, L ;
Vanvelcenaher, J ;
Pelayo, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 89 (3-4) :281-288
[10]   Maximal lactate steady state in rats submitted to swimming exercise [J].
Gobatto, CA ;
de Mello, MAR ;
Sibuya, CY ;
de Azevedo, JRM ;
dos Santos, LA ;
Kokubun, E .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2001, 130 (01) :21-27