An integrated method for spectrum extraction and compound identification from gas chromatography/mass spectrometry data

被引:670
作者
Stein, SE [1 ]
机构
[1] NIST, Mass Spectrometry Data Ctr, Phys & Chem Properties Div, Gaithersburg, MD 29899 USA
关键词
D O I
10.1016/S1044-0305(99)00047-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is presented for extracting individual component spectra from gas chromatography/mass spectrometry (GC/MS) data files and then using these spectra to identify target compounds by matching spectra in a reference Library. It extends a published "model peak" approach which uses selected ion chromatograms as models for component shape. On the basis of this shape, individual mass spectral peak abundance profiles are extracted to produce a "purified" spectrum. In the present work, ion-counting noise is explicitly treated and a number of characteristic features of GC/MS data are taken into account. This allows spectrum extraction to be reliably performed down to very low signal levels and for overlapping components. A spectrum match factor for compound identification is developed that incorporates a number of new corrections, some of which employ information derived from chromatographic behavior. Test results suggest that the ability of this system to identify compounds is comparable to that of conventional analysis.
引用
收藏
页码:770 / 781
页数:12
相关论文
共 14 条
[1]  
BILLER JE, 1974, ANAL LETT, V7, P515
[2]   SPECTRAL DECONVOLUTION FOR OVERLAPPING GC MS COMPONENTS [J].
COLBY, BN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (05) :558-562
[3]  
Davies A.N., 1998, Spectroscopy europe, V3, P24
[4]   EXTRACTION OF MASS-SPECTRA FREE OF BACKGROUND AND NEIGHBORING COMPONENT CONTRIBUTIONS FROM GAS CHROMATOGRAPHY MASS SPECTROMETRY DATA [J].
DROMEY, RG ;
STEFIK, MJ ;
RINDFLEISCH, TC ;
DUFFIELD, AM .
ANALYTICAL CHEMISTRY, 1976, 48 (09) :1368-1375
[5]  
Halket JM, 1999, RAPID COMMUN MASS SP, V13, P279, DOI 10.1002/(SICI)1097-0231(19990228)13:4<279::AID-RCM478>3.0.CO
[6]  
2-I
[7]   IMPROVEMENT OF ALGORITHM FOR PEAK DETECTION IN AUTOMATIC GAS CHROMATOGRAPHY-MASS SPECTROMETRY DATA-PROCESSING [J].
HARGROVE, WF ;
ROSENTHAL, D .
ANALYTICAL CHEMISTRY, 1981, 53 (03) :538-539
[8]   Software-based mass spectral enhancement to remove interferences from spectra of unknowns [J].
Herron, NR ;
Donnelly, JR ;
Sovocool, GW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (06) :598-604
[9]  
KARJALAINEN EJ, 1996, DATA ANAL HYPENATED
[10]  
Peterson D. W., 1978, CONT TOPICS ANALYTIC, V3, P217