摘要
<正>全球每年有超过500万的新发脑卒中患者,我国脑血管病的发病率有逐年增加和年轻化的趋势,死亡率高,致残高、预后差、恢复困难〔1〕。大量证据表明缺血半暗带的持续时间变化差别很大,有些地方长达48 h,而有些地方只有3 h或更短,这主要取决于局部缺血的基本机制和血管的再通率。53项数据的研究表明,急性缺血性脑卒中患者血管再通,血流再灌注可明显提高功能预后、降低死亡率〔2〕。药物溶栓闭塞血管再通率
引用
收藏
页码:5023 / 5025
页数:3
相关论文
共 17 条
[1]   Solitaire FR-A Promising New Device for Acute Ischemic Stroke Treatment [J].
Mokin, Maxim ;
Kass-Hout, Tareq ;
Levy, Elad I. .
WORLD NEUROSURGERY, 2012, 78 (06) :557-558
[2]  
Mechanical thrombectomy with the S olitaire AB device in large intracerebral artery occlusions[J] . John J McCabe,Timothy J Phillips,Con Phatouros,Tejinder Singh,David Blacker,Graeme J Hankey,William McAuliffe.Journal of Medical Imaging and Radiation Oncology . 2012 (2)
[3]  
Acute stroke treatment using the Penumbra endovascular mechanical thrombolysis device: a single-centre experience[J] . R. Gandini,E. Pampana,C. Giudice,F. Massari,S. Spano,E. P. Assako Ondo,E. Salvatori,F. Sallustio,G. Koch,P. Stanzione,G. Simonetti.La radiologia medica . 2012 (7)
[4]  
The Trevo device: preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease[J] . Raul G Nogueira,Elad I Levy,Matthew Gounis,Adnan H Siddiqui.Journal of NeuroInterventional Surgery . 2012 (4)
[5]   Mechanical Thrombectomy Compared to Local-Intraarterial Thrombolysis in Carotid T and Middle Cerebral Artery Occlusions [J].
Moehlenbruch, M. ;
Seifert, M. ;
Okulla, T. ;
Wuellner, U. ;
Hadizadeh, D. R. ;
Nelles, M. ;
Greschus, S. ;
Wilhelm, K. ;
Schild, H. H. ;
Klockgether, T. ;
Urbach, H. .
CLINICAL NEURORADIOLOGY, 2012, 22 (02) :141-147
[6]   Thrombus Branching and Vessel Curvature Are Important Determinants of Middle Cerebral Artery Trunk Recanalization With Merci Thrombectomy Devices [J].
Zhu, Liangfu ;
Liebeskind, David S. ;
Jahan, Reza ;
Starkman, Sidney ;
Salamon, Noriko ;
Duckwiler, Gary ;
Vinuela, Fernando ;
Tateshima, Satoshi ;
Gonzalez, Nestor ;
Villablanca, Pablo ;
Ali, Latisha K. ;
Kim, Doojin ;
Ovbiagele, Bruce ;
Froehler, Michael ;
Tenser, Matthew ;
Saver, Jeffrey L. .
STROKE, 2012, 43 (03) :787-792
[7]  
Trevo System: Single‐Center Experience with a Novel Mechanical Thrombectomy Device[J] . Nuno Mendon?a,Alan Flores,Jorge Pagola,Marta Rubiera,David Rodríguez‐Luna,M. Angels De Miquel,Pere Cardona,Helena Quesada,Paloma Mora,José Alvarez‐Sabín,Carlos Molina,Marc Ribó.Journal of Neuroimaging . 2011 (1)
[8]   Self-Expandable Stents in the Treatment of Acute Ischemic Stroke Refractory to Current Thrombectomy Devices [J].
Linfante, Italo ;
Samaniego, Edgar A. ;
Geisbuesch, Philipp ;
Dabus, Guilherme .
STROKE, 2011, 42 (09) :2636-2638
[9]   Mechanical Thrombectomy for Acute Ischemic Stroke Using the MERCI Retriever and Penumbra Aspiration Systems [J].
Tenser, Matthew S. ;
Amar, Arun P. ;
Mack, William J. .
WORLD NEUROSURGERY, 2011, 76 (06) :S16-S23
[10]   Combining Acute Diffusion-Weighted Imaging and Mean Transmit Time Lesion Volumes With National Institutes of Health Stroke Scale Score Improves the Prediction of Acute Stroke Outcome [J].
Yoo, Albert J. ;
Barak, Elizabeth R. ;
Copen, William A. ;
Kamalian, Shahmir ;
Gharai, Leila Rezai ;
Pervez, Muhammad A. ;
Schwamm, Lee H. ;
Gonzalez, R. Gilberto ;
Schaefer, Pamela W. .
STROKE, 2010, 41 (08) :1728-1735