NON-INVASIVELY AND INVASIVELY MEASURED PULSATILE HEMODYNAMICS WITH GRADED ARTERIAL-STENOSIS

被引:23
作者
FARRAR, DJ
GREEN, HD
PETERSON, DW
机构
[1] Department of Physiology and Pharmacology, Bowman Gray School of Medicine, Winston-Salem, NC
基金
美国国家卫生研究院;
关键词
D O I
10.1093/cvr/13.1.45
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Summary: Pulsatile haemodynamics associated with graded degrees of experimentally produced stenosis were studied in the canine femoral artery. Invasively determined pulsatile blood flow and noninvasively determined blood velocity with Doppler ultrasound were measured an average of 1.3 and 2.3 cm proximal to the stenosis, respectively. Pulsatile blood pressure was measured 0.6 cm proximal and 3.7 cm distal to the stenosis. With increasing severity of stenosis there were progressive increases in the femoral artery hydraulic input impedance moduli and in the ratio of the impedance moduli to the zero harmonic impedance (or total resistance). This resulted in: a) a progressive reduction in the Fourier harmonic moduli and pulsewave amplitudes of flow, velocity, and distal pressure; b) a progressive increase in the fifth-seventh proximal pressure harmonic moduli; but c) little change in mean proximal pressure or its first 4 harmonic moduli. The data confirm the well known phenomena of a 'critical stenosis' in that there is little decrease in resting mean blood flow until there is a 70 to 80 stenosis (area reduction). Also the oscillatory portions of the femoral artery data were more sensitive to the changes in stenosis than were the nonoscillatory parameters, which confirms previously reported findings from the thoracic aorta. However, the femoral artery haemodynamics exhibited a greater amount of frequency dependent behaviour than the thoracic aorta which is probably the result of a more complex interaction of reflections from the stenosis and from the periphery in the femoral artery than in the thoracic aorta. The sensitive changes in oscillatory haemodynamics may provide a useful basis for noninvasive and invasive physiological assessment of human peripheral atherosclerotic stenosis and of experimental stenosis in animals.
引用
收藏
页码:45 / 57
页数:13
相关论文
共 26 条
[1]   CRITICAL STENOSIS OF CAROTID ARTERY IN DOG [J].
EKLOF, B ;
SCHWARTZ, SI .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1970, 25 (04) :349-&
[2]  
FARRAR DJ, 1977, CIRCULATION, V56, P171
[3]  
FARRAR DJ, 1976, FED PROC, V35, P448
[4]  
FARRAR DJ, ANN BIOMEDICAL ENGIN
[5]   MEASUREMENTS OF DISORDERED FLOWS DISTAL TO SUBTOTAL VASCULAR STENOSES IN THORACIC AORTAS OF DOGS [J].
GIDDENS, DP ;
MABON, RF ;
CASSANOVA, RA .
CIRCULATION RESEARCH, 1976, 39 (01) :112-119
[6]  
GOSLING RG, 1973, CARDIOVASCULAR APPLI, pCH22
[7]  
GOSLING RG, 1974, ARTERIES VEINS, pCH5
[8]   EXPERIMENTAL MEASUREMENTS OF TURBULENCE SPECTRA DISTAL TO STENOSES [J].
KIM, BM ;
CORCORAN, WH .
JOURNAL OF BIOMECHANICS, 1974, 7 (04) :335-342
[9]   ANALYSIS OF PRESSURE WAVES AS A MEAN OF DIAGNOSING VASCULAR OBSTRUCTIONS [J].
KIM, BM ;
CORCORAN, WH .
MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (04) :422-430
[10]   MECHANISM OF EFFECT OF CORONARY-ARTERY STENOSIS ON CORONARY FLOW IN DOG [J].
LIPSCOMB, K ;
GOULD, KL .
AMERICAN HEART JOURNAL, 1975, 89 (01) :60-67