SYNTHESIS OF A CORTISOL BIOTIN CONJUGATE AND EVALUATION AS A TRACER IN AN IMMUNOASSAY FOR SALIVARY CORTISOL MEASUREMENT

被引:792
作者
DRESSENDORFER, RA
KIRSCHBAUM, C
ROHDE, W
STAHL, F
STRASBURGER, CJ
机构
[1] UNIV MUNICH,KLINIKUM INNENSTADT,MED KLIN,ZIEMSSENSTR 1,W-8000 MUNICH 2,GERMANY
[2] HUMBOLDT UNIV,BEREICH MED CHARITE,INST EXPTL ENDOCRINOL,O-1040 BERLIN,GERMANY
[3] UNIV TRIER,FACHBEREICH PSYCHOL 1,W-5500 TRIER,GERMANY
关键词
D O I
10.1016/0960-0760(92)90294-S
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cortisol 3-(o-carboxymethyl)oxime (C3-CMO) and a commercially available biotin-hydrazide derivative were used to synthesize a C3-CMO-biotin conjugate. C3-CMO was converted into a N-hydroxysuccinimide ester derivative which in a second reaction step was allowed to interact with the hydrazide derivative of biotin. This simple-to-perform synthesis yielded a conjugate suitable for use as a tracer in immunoassays for cortisol measurement. Employing biotin as the primary probe in a competitive solid phase immunoassay allows for variable end point determination by means of commercially available labeled avidin or streptavidin derivatives. Streptavidin-Europium was used in conjunction with the DELFIA-system for time-resolved fluorometric end point measurement (TR-FIA) throughout the study. In addition, colorimetric end point determination (ELISA) using streptavidin-alkaline phosphatase as a secondary probe was established and evaluated. Both forms of this non-isotopic assay showed excellent correlation with a commercially available radioimmunoassay adapted for salivary cortisol measurement. The lower detection limit was 0.43 nM for a 50 mul salivary sample. The intra-assay coefficient of variation was 6.7, 4.7 and 4.0% at cortisol concentrations of 2.2, 5.5 and 13.2 nM, respectively (n = 37), and the corresponding inter-assay coefficients of variation were 9.0, 8.6 and 7.1 % (n = 50). The competitive immunoassay requires 1.5 h incubation time and shows robust and reproducible performance. The C3-CMO-biotin conjugate allows for sensitive and flexible end point determination of salivary cortisol levels in immunoassays.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 19 条
[1]   SALIVARY CORTISOL-LEVELS IN TRUE AND APPARENT HYPERCORTISOLISM [J].
EVANS, PJ ;
PETERS, JR ;
DYAS, J ;
WALKER, RF ;
RIADFAHMY, D ;
HALL, R .
CLINICAL ENDOCRINOLOGY, 1984, 20 (06) :709-715
[2]   IDENTIFICATION AND MEASUREMENT OF SEX-HORMONE BINDING GLOBULIN (SHBG) AND CORTICOSTEROID BINDING GLOBULIN (CBG) IN HUMAN-SALIVA [J].
HAMMOND, GL ;
LANGLEY, MS .
ACTA ENDOCRINOLOGICA, 1986, 112 (04) :603-608
[3]   A SENSITIVE DIRECT ENZYME-IMMUNOASSAY FOR CORTISOL IN PLASMA AND SALIVA [J].
HUBL, W ;
TAUBERT, H ;
FREYMANN, E ;
MEISSNER, D ;
STAHL, F ;
DORNER, G .
EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY, 1984, 84 (01) :63-70
[4]  
KATZ FH, 1969, J DENT RES, P448
[5]  
KHOSRAVI MJ, 1991, CLIN CHEM, V37, P58
[6]   SALIVARY CORTISOL IN PSYCHOBIOLOGICAL RESEARCH - AN OVERVIEW [J].
KIRSCHBAUM, C ;
HELLHAMMER, DH .
NEUROPSYCHOBIOLOGY, 1989, 22 (03) :150-169
[7]   CORTISOL AND BEHAVIOR .1. ADAPTATION OF A RADIOIMMUNOASSAY KIT FOR RELIABLE AND INEXPENSIVE SALIVARY CORTISOL DETERMINATION [J].
KIRSCHBAUM, C ;
STRASBURGER, CJ ;
JAMMERS, W ;
HELLHAMMER, DH .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1989, 34 (04) :747-751
[8]   SYNTHESIS OF BIOTIN-LABELED DEXAMETHASONE DERIVATIVES - NOVEL HORMONE-AFFINITY PROBES [J].
MANZ, B ;
HEUBNER, A ;
KOHLER, I ;
GRILL, HJ ;
POLLOW, K .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1983, 131 (02) :333-338
[9]   IMMUNOAFFINITY CHROMATOGRAPHY AND A BIOTIN-STREPTAVIDIN AMPLIFIED ENZYME-IMMUNOASSAY FOR SENSITIVE AND SPECIFIC ESTIMATION OF ESTRADIOL-17-BETA [J].
MEYER, HHD ;
SAUERWEIN, H ;
MUTAYOBA, BM .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1990, 35 (02) :263-269
[10]   VALUE OF A SALIVA CORTISOL RADIOIMMUNOASSAY IN THE TESTING OF THE HYPOTHALAMIC-PITUITARY-ADRENAL AXIS [J].
MOORE, CA ;
STALLA, GK ;
MULLER, OA .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 324 (3-4) :260-260