QUANTITATION OF MORPHINE, MORPHINE-3-GLUCURONIDE, AND MORPHINE-6-GLUCURONIDE IN PLASMA AND CEREBROSPINAL-FLUID USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION

被引:54
作者
WRIGHT, AWE
WATT, JA
KENNEDY, M
CRAMOND, T
SMITH, MT
机构
[1] UNIV QUEENSLAND,ROYAL BRISBANE HOSP,DEPT PEDIAT,BRISBANE,QLD 4029,AUSTRALIA
[2] UNIV QUEENSLAND,ROYAL BRISBANE HOSP,DEPT SURG,DIV ANAESTHET,BRISBANE,QLD 4029,AUSTRALIA
关键词
MORPHINE; MORPHINE-3-GLUCURONIDE; MORPHINE-6-GLUCURONIDE; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; ELECTROCHEMICAL DETECTION; SOLID PHASE EXTRACTION;
D O I
10.1097/00007691-199404000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
An original, sensitive, and specific high-performance liquid chromatographic (HPLC) assay was developed for the quantitation of morphine and its two major metabolites, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G), in human plasma and cerebrospinal fluid (CSF) and in rat plasma, using hydromorphone as the internal standard. Solid-phase extraction was used to separate morphine and its glucuronide metabolites from plasma constituents. Extraction efficiencies of morphine, M3G, and M6G from human plasma samples (0.5 ml) were 84, 87, and 88%, respectively. Extraction efficiencies of morphine, M3G, and M6G did not differ significantly (p > 0.05) between human plasma and CSF or rat plasma. Morphine, M3G, M6G, and hydromorphone were separated on a 10 mu C-8 Resolve radially compressed cartridge using a mobile phase comprising methanol:acetonitrile:phosphate buffer, (0.0125M pH 7.5; 10: 10:80), in which 11 mg/L of cetyltrimethylammonium bromide (cetrimide) was dissolved. Quantitation was achieved using a single electrochemical detector at ambient temperature (23-degrees-C). Standard curves were linear over the ranges 0.020-2.190, 0.027-2.709, and 0.027-0.542 muM for morphine, M3G, and M6G, respectively. Lower limits of detection for morphine, M3G, and M6G in human plasma and CSF samples (0.5 ml) were 0.020, 0.027, and 0.027 muM, respectively. Corresponding lower limits of detection in rat plasma (0.1 ml) were 0.102, 0.135, and 0.135 muM, respectively. Intraassay precision for low and high concentrations of morphine, M3G, and M6G were <23 and <8% respectively. Similarly, interassay accuracy for low and medium concentrations of morphine, M3G, and M6G were <17% and were <9% for high concentrations.
引用
收藏
页码:200 / 208
页数:9
相关论文
共 30 条
[1]   MORPHINE-6-GLUCURONIDE - ANALGESIC EFFECTS AND RECEPTOR-BINDING PROFILE IN RATS [J].
ABBOTT, FV ;
PALMOUR, RM .
LIFE SCIENCES, 1988, 43 (21) :1685-1695
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MORPHINE, MORPHINE-3-GLUCURONIDE, MORPHINE-6-GLUCURONIDE AND CODEINE IN BIOLOGICAL SAMPLES USING MULTIWAVELENGTH FORWARD OPTICAL-DETECTION - A REPLY [J].
BOGUSZ, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (01) :189-190
[3]   SIMULTANEOUS SOLID-PHASE EXTRACTION AND CHROMATOGRAPHIC ANALYSIS OF MORPHINE AND HYDROMORPHONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BOUQUILLON, AI ;
FREEMAN, D ;
MOULIN, DE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02) :354-357
[4]   CSF AND BLOOD PHARMACOKINETICS OF HYDROMORPHONE AND MORPHINE FOLLOWING LUMBAR EPIDURAL ADMINISTRATION [J].
BROSE, WG ;
TANELIAN, DL ;
BRODSKY, JB ;
MARK, JBD ;
COUSINS, MJ .
PAIN, 1991, 45 (01) :11-15
[5]  
BRUNK SF, 1974, CLIN PHARMACOL THER, V16, P51
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MORPHINE, MORPHINE-3-GLUCURONIDE, MORPHINE-6-GLUCURONIDE AND CODEINE IN BIOLOGICAL SAMPLES USING MULTIWAVELENGTH FORWARD OPTICAL-DETECTION [J].
CHARI, G ;
GULATI, A ;
BHAT, R ;
TEBBETT, IR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 571 (1-2) :263-270
[7]   THE ENANTIOSELECTIVE GLUCURONIDATION OF MORPHINE IN RATS AND HUMANS - EVIDENCE FOR THE INVOLVEMENT OF MORE THAN ONE UDP-GLUCURONOSYLTRANSFERASE ISOENZYME [J].
COUGHTRIE, MWH ;
ASK, B ;
RANE, A ;
BURCHELL, B ;
HUME, R .
BIOCHEMICAL PHARMACOLOGY, 1989, 38 (19) :3273-3280
[8]   A SIMPLE, RAPID METHOD FOR THE SIMULTANEOUS DETERMINATION OF MORPHINE AND ITS PRINCIPAL METABOLITES IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUOROMETRIC DETECTION [J].
GLARE, PA ;
WALSH, TD ;
PIPPENGER, CE .
THERAPEUTIC DRUG MONITORING, 1991, 13 (03) :226-232
[9]   ANTINOCICEPTIVE AND VENTILATORY EFFECTS OF THE MORPHINE METABOLITES - MORPHINE-6-GLUCURONIDE AND MORPHINE-3-GLUCURONIDE [J].
GONG, QL ;
HEDNER, T ;
HEDNER, J ;
BJORKMAN, R ;
NORDBERG, G .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1991, 193 (01) :47-56
[10]  
GONG QL, 1992, PAIN, V48, P249, DOI 10.1016/0304-3959(92)90065-J