SEQUENTIAL CHROMATOGRAM RATIO TECHNIQUE - EVALUATION OF THE EFFECTS OF RETENTION TIME PRECISION, ADSORPTION-ISOTHERM LINEARITY, AND DETECTOR LINEARITY ON QUALITATIVE AND QUANTITATIVE-ANALYSIS

被引:16
作者
BAHOWICK, TJ [1 ]
SYNOVEC, RE [1 ]
机构
[1] UNIV WASHINGTON,CTR PROC ANALYT CHEM,DEPT CHEM BG-10,SEATTLE,WA 98195
关键词
D O I
10.1021/ac00029a008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study of the sequential chromatogram ratio technique was done to characterize and correct for retention time variation, peak-shape change due to concentrations exceeding the adsorption isotherm linear range, and mild detector nonlinearity over a broad concentration range. A sensitive minimization routine was developed to overlay chromatographic peaks from sequential injections using a simple displacement along the time axis. Precise peak alignment to within 0.8 % of the baseline peak width was necessary for qualitative interpretation of the ratio chromatogram. For quantitation of the ratio of injected concentrations for pure-component peaks, time shifts as large as 2.5 % of the base-line peak width caused a negative bias of 1 % or less. A peak-shape analysis method, based on the scaled point-by-point difference of normalized peaks, was adapted as a diagnostic test for peak-shape change and as a means of correcting the ratio value of Injected concentrations. At a concentration 4 times the linear isotherm limit, the ratio chromatogram was distorted, and the estimated correction to the ratio value was +2.3 % of the true value. Thus, restriction of the ratio technique to within the linear isotherm region is recommended. A nonlinear power-law detector model, which preserved the qualitative features of the ratio chromatogram, was easily incorporated into the quantitation method. Detector nonlinearity corrections to the ratio values, equal to +2.0% and +5.8%, were obtained when the true ratios of injected concentrations were 2.0 and 8.0, respectively.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 29 条
[1]  
BALKE ST, 1984, QUANTITATIVE COLUMN, P60
[2]  
CARR PW, 1980, ANAL CHEM, V52, P1746
[3]   PEAK DISTORTION IN CHROMATOGRAPHY .1. CONCENTRATION-DEPENDENT BEHAVIOR [J].
CONDER, JR .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (07) :341-348
[4]   PEAK DISTORTION IN CHROMATOGRAPHY .2. KINETICALLY CONTROLLED FACTORS [J].
CONDER, JR .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (08) :397-403
[5]   THE PHYSICAL SENSE OF SIMULATION-MODELS OF LIQUID-CHROMATOGRAPHY - PROPAGATION THROUGH A GRID OR SOLUTION OF THE MASS BALANCE EQUATION [J].
CZOK, M ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :189-200
[6]  
DOLAN JW, 1990, LC GC, V11, P842
[7]   CHARACTERIZATION OF EXTRACOLUMN AND CONCENTRATION-DEPENDENT DISTORTION OF CHROMATOGRAPHIC PEAKS BY EDGEWORTH-CRAMER SERIES [J].
DONDI, F ;
REMELLI, M .
JOURNAL OF CHROMATOGRAPHY, 1984, 315 (DEC) :67-73
[8]   LC DETECTORS - EVALUATION AND PRACTICAL IMPLICATIONS OF LINEARITY [J].
DORSCHEL, CA ;
EKMANIS, JL ;
OBERHOLTZER, JE ;
WARREN, FV ;
BIDLINGMEYER, BA .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :A951-&
[9]   BIAS AND NONLINEARITY OF ULTRAVIOLET CALIBRATION CURVES MEASURED USING DIODE-ARRAY DETECTORS [J].
DOSE, EV ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2571-2579
[10]   CALIBRATING DETECTOR RESPONSES USING CHROMATOGRAPHIC PEAK SHAPES [J].
DOSE, EV ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :816-820