NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY

被引:262
作者
ARAUJO, LI
LAMMERTSMA, AA
RHODES, CG
MCFALLS, EO
IIDA, H
RECHAVIA, E
GALASSI, A
DESILVA, R
JONES, T
MASERI, A
机构
[1] HAMMERSMITH HOSP, MRC, CYCLOTRON UNIT, LONDON W12 0HS, ENGLAND
[2] HAMMERSMITH HOSP, MRC, CARDIOVASC UNIT, LONDON W12 0HS, ENGLAND
关键词
MYOCARDIAL BLOOD FLOW; POSITRON EMISSION TOMOGRAPHY; O-15-LABELED WATER;
D O I
10.1161/01.CIR.83.3.875
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Oxygen-15-labeled water is a diffusible, metabolically inert myocardial blood flow tracer with a short half-life (2 minutes) that can be used quantitatively with positron emission tomography (PET). The purpose of this study was to validate a new technique to quantify myocardial blood flow (MBF) in animals and to assess its application in patients. Methods and Results. The technique involves the administration of O-15-labeled carbon dioxide ((CO2)-O-15) and rapid dynamic scanning. Arterial and myocardial time activity curves were fitted to a single tissue compartment tracer kinetic model to estimate MBF in each myocardial region. Validation studies consisted of 52 simultaneous measurements of MBF with PET and gamma-labeled microspheres in nine closed-chest dogs over a flow range of 0.5-6.1 ml/g/min. A good correlation between the two methods was obtained (y = 0.36 + 1.0x, r = 0.91). Human studies consisted of 11 normal volunteers and eight patients with chronic stable angina and single-vessel disease, before and after intravenous dipyridamole infusion. In the normal group, MBF was homogeneous throughout the left ventricle both at rest and after administration of dipyridamole (0.88 +/- 0.08 ml/g/min and 3.52 +/- 1.12 ml/g/min, respectively; p less-than-or-equal-to 0.001). In patients, resting MBF was similar in the distribution of the normal and stenotic arteries (1.03 +/- 0.23 and 0.93 +/- 0.21 ml/g/min, respectively). After dipyridamole infusion, MBF in normally perfused areas increased to 2.86 +/- 0.83 ml/g/min, whereas in the regions supplied by stenotic arteries it increased to only 1.32 +/- 0.27 ml/g/min (p less-than-or-equal-to 0.001). Conclusions. PET with (CO2)-O-15 inhalation provides an accurate noninvasive quantitative method for measuring regional myocardial blood flow in patients.
引用
收藏
页码:875 / 885
页数:11
相关论文
共 34 条
[1]  
Altman P. L., 1971, RESPIRATION CIRCULAT
[2]   MYOCARDIAL BLOOD-FLOW DISTRIBUTION DURING ISCHEMIA-INDUCED CORONARY VASODILATION IN UNANESTHETIZED DOG [J].
BACHE, RJ ;
COBB, FR ;
GREENFIELD, JC .
JOURNAL OF CLINICAL INVESTIGATION, 1974, 54 (06) :1462-1472
[3]   ASSESSMENT OF REGIONAL MYOCARDIAL PERFUSION BY POSITRON EMISSION TOMOGRAPHY AFTER INTRA-CORONARY ADMINISTRATION OF GA-68 LABELED ALBUMIN MICROSPHERES [J].
BELLER, GA ;
ALTON, WJ ;
COCHAVI, S ;
HNATOWICH, D ;
BROWNELL, GL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (04) :447-452
[4]  
BERGMANN SR, 1980, CIRCULATION, V61, P34, DOI 10.1161/01.CIR.61.1.34
[5]   NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY [J].
BERGMANN, SR ;
HERRERO, P ;
MARKHAM, J ;
WEINHEIMER, CJ ;
WALSH, MN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :639-652
[6]   QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15 [J].
BERGMANN, SR ;
FOX, KAA ;
RAND, AL ;
MCELVANY, KD ;
WELCH, MJ ;
MARKHAM, J ;
SOBEL, BE .
CIRCULATION, 1984, 70 (04) :724-733
[7]   INFARCTION SIZING AND MYOCARDIAL PERFUSION MEASUREMENTS USING RUBIDIUM-82 AND POSITRON EMISSION TOMOGRAPHY [J].
BUDINGER, TF ;
YANO, Y ;
DERENZO, SE ;
HUESMAN, RH ;
YEN, CK ;
MOYER, BR ;
SHERMAN, LG .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) :399-399
[8]  
CLARK JC, 1975, SHORT LIVED RADIOACT, P122
[9]   EVIDENCE OF LIMITATIONS OF WATER AS A FREELY DIFFUSIBLE TRACER IN BRAIN OF RHESUS-MONKEY [J].
EICHLING, JO ;
RAICHLE, ME ;
GRUBB, RL ;
TERPOGOS.MM .
CIRCULATION RESEARCH, 1974, 35 (03) :358-364
[10]   COMPARISON OF MAGNETIC-RESONANCE IMAGING AND ECHOCARDIOGRAPHY IN DETERMINATION OF CARDIAC DIMENSIONS IN NORMAL SUBJECTS [J].
FRIEDMAN, BJ ;
WATERS, J ;
KWAN, OL ;
DEMARIA, AN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (06) :1369-1376