INVIVO MEASUREMENT OF MICROVASCULATURE - METHOD FOR REPEATED AND REPRODUCIBLE QUANTITATION DURING LONG-TERM EXPERIMENTS

被引:5
作者
DIMITRIEVICH, GS [1 ]
FISCHERDZOGA, K [1 ]
LEE, RM [1 ]
GRIEM, ML [1 ]
机构
[1] UNIV CHICAGO,CHICAGO TUMOR INST,CHICAGO,IL 60637
关键词
D O I
10.1016/0026-2862(79)90015-3
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
A method for long-term, reproducible observation of mature microvasculature is proposed using Sandison-Clark rabbit ear chambers. Forty-nine high-magnification (320 ×) in vivo photomicrographs, reproducible in position to a 10-μm accuracy with no overlap, are taken on each data-point day. They cover 1.617 mm2 of vascular membrane of a standard 0.025-mm thickness. For the purpose of analysis, vessels are divided into two groups: vessels > 10 and ≤ 10 μm in diameter. Vascular lengths and surface areas are measured directly from the photomicrographs projected at a fixed distance. These parameters are measured on Days 1, 5, 10, 20, and 30. Vascular length (> 10 μm, 8.35 mm ± 0.66; ≤ 10 μm, 11.99 mm ± 1.31) and vascular surface area (> 10 μm, 0.168 mm2 ± 9.88 × 10-3; ≤ 10 μm, 0.079 mm2 ± 4.21 × 10-3) obtained over a 30-day observation period indicate the reproducibility of the method. The intervascular supportive tissue area is calculated by subtracting the total microvascular surface area from the total tissue area. A dilatation factor has been derived which allows a comparison of the ratios of total microvascular surface area per unit vascular length over time. From the measured parameters, a number of important morphometric values can be calculated, e.g., vascular and supportive tissue volumes. Physiological changes are expressed as functions of masured parameters over time, with each specimen serving as its own control. These quantitative measurements are made possible by high-magnification photomicrography, which simultaneously allows qualitative analysis at the cellular level. This method should prove useful as a tool for quantitative and qualitative determination of changes in the microvasculature due to various local and systemic injuries. © 1979.
引用
收藏
页码:18 / 32
页数:15
相关论文
共 48 条
[1]   STUDIES ON THE PATHOGENESIS OF ACUTE INFLAMMATION .1. THE INFLAMMATORY REACTION TO THERMAL INJURY AS OBSERVED IN THE RABBIT EAR CHAMBER [J].
ALLISON, F ;
SMITH, MR ;
WOOD, WB .
JOURNAL OF EXPERIMENTAL MEDICINE, 1955, 102 (06) :655-&
[2]   A CARBON-GELATIN INJECTION MASS FOR MINUTE VASCULAR AND RESPIRATORY PASSAGES [J].
ANGULO, AW ;
HESSERT, EC ;
KOWNACKI, VP .
STAIN TECHNOLOGY, 1958, 33 (02) :63-66
[3]   METHOD FOR IN-LINE MEASUREMENT OF LUMEN AND WALL OF MICROSCOPIC VESSELS IN-VIVO [J].
BAEZ, S .
MICROVASCULAR RESEARCH, 1973, 5 (03) :299-308
[4]   OPEN CREMASTER MUSCLE PREPARATION FOR STUDY OF BLOOD-VESSELS BY IN-VIVO MICROSCOPY [J].
BAEZ, S .
MICROVASCULAR RESEARCH, 1973, 5 (03) :384-394
[5]   LOW-DOSE X-RADIATION DAMAGE TO CAPILLARIES OF MOUSE SMALL-INTESTINE CORRELATED HISTOLOGIC AND MICROANGIOGRAPHIC STUDY [J].
BOYER, NH ;
CONGER, AD .
INVESTIGATIVE RADIOLOGY, 1972, 7 (05) :418-&
[6]  
Chalkley HW, 1943, J NATL CANCER I, V4, P47
[7]   Microscopic observations on the growth of blood capillaries in the living mammal [J].
Clark, ER ;
Clark, EL .
AMERICAN JOURNAL OF ANATOMY, 1939, 64 (02) :251-301
[8]  
CONWAY H, 1957, Plast Reconstr Surg (1946), V20, P103, DOI 10.1097/00006534-195708000-00002
[9]   RADIATION-DAMAGE AND SUBENDOTHELIAL REPAIR TO RABBIT EAR CHAMBER MICROVASCULATURE - INVIVO AND HISTOLOGIC STUDY [J].
DIMITRIEVICH, GS ;
HAUSLADEN, SL ;
KUCHNIR, FT ;
GRIEM, ML .
RADIATION RESEARCH, 1977, 69 (02) :276-292
[10]   CHANGES IN CONNECTIVE TISSUE REACTION INDUCED BY CORTISONE [J].
EBERT, RH ;
BARCLAY, WR .
ANNALS OF INTERNAL MEDICINE, 1952, 37 (03) :506-518