EVALUATION OF THE REPRODUCIBILITY AND ACCURACY OF AMBULATORY BLOOD-PRESSURE MONITORING USING THE TAKEDA TM-2420 AUTOMATED BLOOD-PRESSURE MONITOR

被引:10
作者
KELLY, JJ [1 ]
HUNYOR, SN [1 ]
HO, KY [1 ]
机构
[1] ROYAL N SHORE HOSP,DEPT CARDIOL,CARDIOVASC RES UNIT,SYDNEY,AUSTRALIA
关键词
D O I
10.3109/10641969309032934
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The reproducibility of ambulatory blood pressure measurements was assessed in eight normotensive subjects who underwent three separate days of recording, using Takeda Medical TM-2420 (TM-2420) blood pressure monitors. The coefficients of variation of mean 24 hour systolic and diastolic blood pressure were 2.1% and 2.8% respectively. The corresponding values for systolic and diastolic blood pressure variability, were 19% and 14% respectively. Measurement intervals of greater than 30 minutes significantly reduced the reproducibility of mean day interval systolic measurements. The bias of the TM-2420 systolic and diastolic blood pressure measurements compared to standard sphygmomanometer measurement were, 0 +/- 7 mmHg and 1 +/- 6 mmHg respectively. Ambulatory blood pressure monitoring provides reproducible estimates of mean systolic and diastolic blood pressure, however, blood pressure variability is poorly reproducible.
引用
收藏
页码:271 / 287
页数:17
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
CONWAY J, 1989, J HYPERTENS, V7, pS29
[3]  
CONWAY J, 1991, J HYPERTENS S, V3, pS57
[4]   AMBULATORY BLOOD-PRESSURE RECORDINGS - REPRODUCIBILITY AND UNPREDICTABILITY [J].
DESCOMBES, BJ ;
PORCHET, M ;
WAEBER, B ;
BRUNNER, HR .
HYPERTENSION, 1984, 6 (01) :110-114
[5]   CONTINUOUS VS INTERMITTENT BLOOD-PRESSURE MEASUREMENTS IN ESTIMATING 24-HOUR AVERAGE BLOOD-PRESSURE [J].
DIRIENZO, M ;
GRASSI, G ;
PEDOTTI, A ;
MANCIA, G .
HYPERTENSION, 1983, 5 (02) :264-269
[6]   SAMPLE-SIZE FOR SHORT-TERM TRIALS OF ANTIHYPERTENSIVE DRUGS [J].
FREESTONE, S ;
SILAS, JH ;
RAMSAY, LE .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 14 (02) :265-268
[7]   BENCH AND AMBULATORY FIELD-EVALUATION OF THE A AND D TM-2420 AUTOMATED SPHYGMOMANOMETER [J].
JAMIESON, MJ ;
FOWLER, G ;
MACDONALD, TM ;
WEBSTER, J ;
WITTE, K ;
LAWSON, L ;
CRICHTON, W ;
JEFFERS, TA ;
PETRIE, JC .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :599-605
[8]   ARTERIAL BLOOD PRESSURE MEASUREMENTS WITH PORTABLE RECORDER IN HYPERTENSIVE PATIENTS .I. VARIABILITY + CORRELATION WITH CASUAL PRESSURES [J].
KAIN, HK ;
SOKOLOW, M ;
HINMAN, AT .
CIRCULATION, 1964, 30 (06) :882-&
[9]   AMBULANT BLOOD-PRESSURE - REPRODUCIBILITY AND THE ASSESSMENT OF INTERVENTIONS [J].
MANN, S ;
CRAIG, MWM ;
BALASUBRAMANIAN, V ;
CASHMAN, PMM ;
RAFTERY, EB .
CLINICAL SCIENCE, 1980, 59 (06) :497-500
[10]  
OBRIEN E, 1991, J HYPERTENS, V9, P571