EXTRACRANIAL CAROTID ARTERIES - EVALUATION WITH BLACK BLOOD MR ANGIOGRAPHY

被引:120
作者
EDELMAN, RR
MATTLE, HP
WALLNER, B
BAJAKIAN, R
KLEEFIELD, J
KENT, C
SKILLMAN, JJ
MENDEL, JB
ATKINSON, DJ
机构
[1] BETH ISRAEL HOSP,DEPT SURG,BOSTON,MA 02215
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02115
[3] NEW ENGLAND DEACONESS HOSP,DEPT RADIOL,BOSTON,MA 02215
[4] SIEMENS MED SYST INC,ISELIN,NJ
关键词
Carotid arteries; MR studies; stenosis or occlusion; Magnetic resonance (MR); image processing; pulse sequences;
D O I
10.1148/radiology.177.1.2399337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors evaluated the accuracy of 'black blood' magnetic resonance (MR) angiography for depicting disease involving the extracranial carotid arteries. Two- and three-dimensional flow-compensated gradient-echo sequences were employed to create 'bright blood' images. A thin-section spin-echo sequence with flow presaturation allowed the creation of black blood images. Projection angiograms were made from bright and black blood images with application of a maximum- or minimum-intensity projection algorithm, respectively. These methods were used in 13 healthy volunteers and 17 patients, and a prospective blinded comparison of MR angiography and conventional angiography was performed. Normal carotid arteries were well shown with both bright and black blood methods; in patients, both methods were sensitive for detecting carotid disease. However, bright blood angiography exaggerated the severity of carotid lesions in 13 of 33 arteries, mostly in severe disease; this problem was not encountered with black blood angiography. The authors conclude that bright blood angiography is a sensitive method for screening carotid disease; when a significant abnormality is found, black blood angiography should be performed for more precise delineation of the lesion.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 21 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]  
DANIELS DL, 1986, AM J NEURORADIOL, V7, P1036
[3]   PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE [J].
DIXON, WT ;
DU, LN ;
FAUL, DD ;
GADO, M ;
ROSSNICK, S .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) :454-462
[4]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[5]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[6]   TIME-RESOLVED MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
YOSHITOME, E .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (03) :275-286
[7]   FRODO PULSE SEQUENCES - A NEW MEANS OF ELIMINATING MOTION, FLOW, AND WRAPAROUND ARTIFACTS [J].
EDELMAN, RR ;
ATKINSON, DJ ;
SILVER, MS ;
LOAIZA, FL ;
WARREN, WS .
RADIOLOGY, 1988, 166 (01) :231-236
[8]   PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, H ;
ZHAO, B ;
LIU, C ;
KIM, D ;
LAUB, G .
RADIOLOGY, 1989, 172 (02) :351-357
[9]   INTRACEREBRAL ARTERIOVENOUS-MALFORMATIONS - EVALUATION WITH SELECTIVE MR ANGIOGRAPHY AND VENOGRAPHY [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, HP ;
OREILLY, GV ;
CANDIA, G ;
CHENG, L ;
BIN, Z ;
KJELLBERG, RN ;
DAVIS, KR .
RADIOLOGY, 1989, 173 (03) :831-837
[10]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564