DISTINGUISHING CAROTID-ARTERY PSEUDO-OCCLUSION WITH COLOR-FLOW DOPPLER

被引:55
作者
BERMAN, SS
DEVINE, JJ
ERDOES, LS
HUNTER, GC
机构
[1] Section of Vascular Surgery, University of Arizona Health Sciences Center, Tucson, AZ
关键词
CAROTID ARTERY DISEASES; ULTRASONICS;
D O I
10.1161/01.STR.26.3.434
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose This study was undertaken to determine the impact of color-flow Doppler on the accuracy of noninvasive carotid imaging for distinguishing an internal carotid artery pseudo-occlusion (string sign) from a complete occlusion. Methods From January 1985 to January 1994, review of noninvasive vascular studies, arteriograms, and operative reports of 26 consecutive patients undergoing 27 carotid endarterectomies for carotid pseudo-occlusion was performed. Further review was conducted of all patients identified with carotid occlusion by noninvasive testing who underwent confirmatory arteriography during the same interval. Results Conventional gray-scale duplex scanning (January 1985 to December 1989) correctly identified 3 of 11 (27%) pseudo-occluded internal carotid arteries compared with 15 of 16 (94%) internal carotid artery pseudo-occlusions correctly identified by color-flow Doppler (January 1990 to June 1994) (P<.01). Similarly, carotid occlusion was more accurately identified by color-flow Doppler (33 of 33, 100%) compared with gray-scale duplex scanning (19 of 27, 90%) (P<.01). Conclusions The addition of color-flow Doppler to the duplex evaluation of the extracranial carotid circulation improves the accuracy of distinguishing carotid pseudo-occlusion from the occluded internal carotid artery and may obviate the need for arteriography to identify patients with this critical level of carotid stenosis.
引用
收藏
页码:434 / 438
页数:5
相关论文
共 20 条
[1]   CRITICAL CAROTID-ARTERY STENOSIS - DIAGNOSIS, TIMING OF SURGERY, AND OUTCOME [J].
BERMAN, SS ;
BERNHARD, VM ;
ERLY, WK ;
MCINTYRE, KE ;
ERDOES, LS ;
HUNTER, GC .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (04) :499-510
[2]   THE LIMITATIONS OF DIAGNOSIS OF CAROTID OCCLUSION BY DOPPLER ULTRASOUND [J].
BORNSTEIN, NM ;
BELOEV, ZG ;
NORRIS, JW .
ANNALS OF SURGERY, 1988, 207 (03) :315-317
[3]   CLINICAL CORRELATES OF DOPPLER ULTRASOUND ERRORS IN THE DETECTION OF INTERNAL CAROTID-ARTERY OCCLUSION [J].
BRIDGERS, SL .
STROKE, 1989, 20 (05) :612-615
[4]  
Chervu A, 1994, Ann Vasc Surg, V8, P296, DOI 10.1007/BF02018179
[6]  
Comeaux ME, 1994, J VASC TECH, V18, P85
[7]  
DALY LE, 1991, INTERPRETATION USES, P248
[8]   THE ROLE OF DUPLEX SCANNING AND ARTERIOGRAPHY BEFORE CAROTID ENDARTERECTOMY - A PROSPECTIVE-STUDY [J].
DAWSON, DL ;
ZIERLER, RE ;
STRANDNESS, DE ;
CLOWES, AW ;
KOHLER, TR .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (04) :673-683
[9]   IS DUPLEX SCANNING SUFFICIENT EVALUATION BEFORE CAROTID ENDARTERECTOMY [J].
GEUDER, JW ;
LAMPARELLO, PJ ;
RILES, TS ;
GIANGOLA, G ;
IMPARATO, AM .
JOURNAL OF VASCULAR SURGERY, 1989, 9 (02) :193-201
[10]   DIFFERENTIATING SUBTOTAL CAROTID-ARTERY STENOSES FROM OCCLUSIONS BY COLOR-CODED DUPLEX SONOGRAPHY [J].
GORTLER, M ;
NIETHAMMER, R ;
WIDDER, B .
JOURNAL OF NEUROLOGY, 1994, 241 (05) :301-305