COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES

被引:321
作者
DOUGLAS, DJ [1 ]
FRENCH, JB [1 ]
机构
[1] UNIV TORONTO,INST AEROSPACE STUDIES,TORONTO M5S 1A1,ONTARIO,CANADA
关键词
D O I
10.1016/1044-0305(92)87067-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The transmission of ions through a conventional two-dimensional radiofrequency-only (rf) quadrupole has been studied for comparatively high operating pressures between 5 x 10(-4) and 1 x 10(-2) torr. Measurements of signals from mass-resolved analyte ions and total ion currents show that, provided the initial injection ion energy is low (1-30 eV), the ion transmission observed through a small aperture at the exit of the rf quadrupole first increases as the gas pressure increases, reaching a maximum at approximately 8 X 10(-3) torr before decreasing at higher pressures. This is in direct contrast to the expectations of classical scattering. This "collisional focusing" appears to be analogous to effects seen in three-dimensional ion traps. The collisional focusing increases with the mass of the ion (not mass-to-charge ratio) for masses up to at least 16,950 u. The collisional focusing of the ions is found to be accompanied by significant losses of axial kinetic energy. A Monte Carlo simulation of the energy loss process is reported that can provide agreement with the observed losses for reasonable collision cross-sections. The results suggest that operation of rf quadrupoles at relatively high pressure may find practical application in sampling ions from high (e.g., atmospheric) pressure ion sources.
引用
收藏
页码:398 / 408
页数:11
相关论文
共 22 条
[1]   MASS-SPECTROMETRY WITH ION SOURCES OPERATING AT ATMOSPHERIC-PRESSURE [J].
BRUINS, AP .
MASS SPECTROMETRY REVIEWS, 1991, 10 (01) :53-77
[2]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[3]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[4]  
Covey T R, 1988, Rapid Commun Mass Spectrom, V2, P249, DOI 10.1002/rcm.1290021111
[5]  
DARCIE TE, 1983, 269 U TOR I AER STUD
[6]  
Dawson P.H., 1976, QUADRUPOLE MASS SPEC
[7]   THE USE OF TRIPLE QUADRUPOLES FOR SEQUENTIAL MASS-SPECTROMETRY .1. THE INSTRUMENT PARAMETERS [J].
DAWSON, PH ;
FRENCH, JB ;
BUCKLEY, JA ;
DOUGLAS, DJ ;
SIMMONS, D .
ORGANIC MASS SPECTROMETRY, 1982, 17 (05) :205-211
[8]   THE EFFECTIVE CONTAINMENT OF PARENT IONS AND DAUGHTER IONS IN TRIPLE QUADRUPOLES USED FOR COLLISIONAL DISSOCIATION [J].
DAWSON, PH ;
FULFORD, JE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1982, 42 (03) :195-211
[9]  
DAWSON PH, 1983, TANDEM MASS SPECTROM, P125
[10]  
Dehmelt HG., 1968, ADV ATOM MOL OPT PHY, V3, P53, DOI [10.1016/s0065-2199(08)60170-0, DOI 10.1016/S0065-2199(08)60170-0]