摘要
One of the key requirements for the validation of chromatographic methods is to determine the purity of a chromatographic peak. Statistical modelling of the chromatographic process suggests that overlapping components are highly probable in a chromatogram. Hence extensive efforts have been directed at the development of sensitive, reliable and robust methods to assess peak purity. This is especially the case in the pharmaceutical industry, where liquid chromatography (LC) is widely utilized and the demands on method validation are justifiably high. On-line multiwavelength absorptiometric detection is often used to generate the additional data required to facilitate peak-purity assessment in LC. This approach, using photodiode-array technology, is directly compatible with the aqueous-based reversed-phase LC solvents used extensively in drug analysis. Consequently, this work highlights many of the peak-purity algorithms, which may be applied using LC with diode-array detection. The relative merits of the individual techniques are discussed, and a rationale is developed for their application.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 93 条
[1]  
ALFREDSON T, 1985, AM LAB, V17, P40
[2]   DECONVOLUTION OF SPECTRA BY LEAST-SQUARES FITTING [J].
ALLEN, GC ;
MCMEEKING, RF .
ANALYTICA CHIMICA ACTA-COMPUTER TECHNIQUES AND OPTIMIZATION, 1978, 2 (01) :73-108
[3]   DE-TAILING AND SHARPENING OF RESPONSE PEAKS IN GAS CHROMATOGRAPHY [J].
ASHLEY, JW ;
REILLEY, CN .
ANALYTICAL CHEMISTRY, 1965, 37 (06) :626-&
[4]   IDENTIFICATION OF DRUGS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY WITH DUAL WAVELENGTH ULTRAVIOLET DETECTION [J].
BAKER, JK ;
SKELTON, RE ;
MA, C .
JOURNAL OF CHROMATOGRAPHY, 1979, 168 (02) :417-427
[5]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[7]   VARIABLE TIME-CONSTANT DIFFERENTIATION IN CHROMATOGRAPHY [J].
BERRIDGE, JC ;
ANDREWS, KS .
ANALYST, 1984, 109 :287-289
[8]   ARTIFICIAL-INTELLIGENCE TECHNIQUES FOR PEAK HOMOGENEITY VALIDATION IN LIQUID-CHROMATOGRAPHY [J].
BRIDGE, TP ;
WILLIAMS, MH ;
FELL, AF .
JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01) :59-67
[9]   COMPARATIVE-EVALUATION OF METHODS FOR ASSESSING PEAK HOMOGENEITY IN LIQUID ISOCRATIC REVERSED-PHASE CHROMATOGRAPHY [J].
BRIDGE, TP ;
WILLIAMS, MH ;
FELL, AF .
ANALYTICA CHIMICA ACTA, 1989, 223 (01) :175-182
[10]  
BROWN SD, 1990, ANAL CHEM, V62, pR84, DOI 10.1021/ac00211a030