ACCURACY OF HIGH-RESOLUTION COMPUTED-TOMOGRAPHY IN DIRECT DIAGNOSIS OF CEREBRAL ANEURYSMS

被引:70
作者
SCHMID, UD
STEIGER, HJ
HUBER, P
机构
[1] UNIV HOSP BERNE, DEPT NEURORADIOL, Bern, SWITZERLAND
[2] UNIV HOSP BERNE, DEPT NEUROSURG, Bern, SWITZERLAND
关键词
D O I
10.1007/BF00327540
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
With high resolution computed tomography (CT) of the skull, performing rapid series of 1.5 mm slices during an intravenous bolus injection of contrast medium, and angiography-like image (angio-CT) of the basal cerebral arteries can be obtained. From 76 consecutive angiographically or autopsy-verified cerebral aneurysms of various size down to 3 mm in diameter, 74 (97.4%) were shown up by the angio-CT. One ruptured and one incidental aneurysm escaped CT visualization. Besides the correct localization of the aneurysms, angio-CT provides information concerning the size and main direction of the aneurysms and yields, in addition, a coronal view of the aneurysms and their surrounding structures. Pitfalls for mis-diagnosis can be the following: Aneurysms of below 5 mm in diameter, located at the supraclinoid part of the carotid artery, multiple or non-ruptured aneurysms, bony or movement artefacts, poorly contrasted vessels due to wrong injection technique of contrast medium or vasospasm, and incorrect interpretation.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 30 条
[1]   COMPUTED-TOMOGRAPHY IN ANEURYSMAL SUBARACHNOID HEMORRHAGE [J].
BELL, BA ;
KENDALL, BE ;
SYMON, L .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1980, 43 (06) :522-524
[2]  
Bosley T M, 1983, Neurol Clin, V1, P929
[3]  
BRISMAR J, 1979, ACTA RADIOL DIAGN, V20, P849, DOI 10.1177/028418517902000601
[4]  
CARMODY RF, 1984, CRC CR REV DIAGN IM, V23, P1
[5]  
DAVIS KR, 1982, RADIOL CLIN N AM, V20, P87
[6]  
Drake C, 1976, CURRENT CONTROVERSIE, P274
[7]  
ESPOSITO S, 1984, NEUROCHIRURGIA, V27, P150
[8]  
FINDLAY GFG, 1980, SURG NEUROL, V13, P125
[9]  
FISCHER M, 1984, THESIS U BERN
[10]   RELATION OF CEREBRAL VASOSPASM TO SUBARACHNOID HEMORRHAGE VISUALIZED BY COMPUTERIZED TOMOGRAPHIC SCANNING [J].
FISHER, CM ;
KISTLER, JP ;
DAVIS, JM .
NEUROSURGERY, 1980, 6 (01) :1-9