PHYSIOLOGICAL-BASIS OF MYOCARDIAL PERFUSION IMAGING WITH THE TECHNETIUM 99M AGENTS

被引:82
作者
BELLER, GA
WATSON, DD
机构
[1] Nuclear Cardiology Laboratory, Division of Cardiology, Department of Medicine, Charlottesville, VA
关键词
D O I
10.1016/S0001-2998(05)80038-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years, several technetium 99m-labeled myocardial perfusion agents have been under investigation to determine their utility in assessing regional myocardial blood flow and cellular viability. 99mTc sestamibi (2-methoxyisobutyl isonitrile), one of the most promising of these agents, is a lipophilic cation that is sequestered largely within mitochondria by the large negative transmembrane potential. Experimental studies have shown that this agent is taken up in the myocardium in proportion to blood flow, but like other diffusible radionuclides underestimates flow at high flow rates. Fractional extraction (Emax) for 99mTc sestamibi is lower than that for thallium 201, but net myocardial uptake is comparable between the two radionuclides. Compared with 201Tl, 99mTc sestamibi does not significantly redistribute. Studies have shown that 99mTc sestamibi uptake after reperfusion, preceded by varying periods of coronary occlusion, reflects the degree of myocardial salvage and viability. 99mTc teboroxime, another promising new perfusion agents, is a boronic acid adduct of technetium dioxime complexes. Emax of 99mTc teboroxime is higher than Emax for 201Tl, but myocardial washout is very rapid (half-life=21 minutes). Myocardial uptake is proportional to regional flow as found with 99mTc sestamibi and 201Tl. © 1991 W.B. Saunders Company. All rights reserved.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 20 条
[1]   ARE THE KINETICS OF TC-99M METHOXYISOBUTYL ISONITRILE AFFECTED BY CELL-METABOLISM AND VIABILITY [J].
BEANLANDS, RSB ;
DAWOOD, F ;
WEN, WH ;
MCLAUGHLIN, PR ;
BUTANY, J ;
DAMATI, G ;
LIU, PP .
CIRCULATION, 1990, 82 (05) :1802-1814
[2]   RELATIONS OF THE MYOCARDIAL IMAGING AGENTS TC-99M-MIBI AND TL-201 TO MYOCARDIAL BLOOD-FLOW IN A CANINE MODEL OF MYOCARDIAL ISCHEMIC INSULT [J].
CANBY, RC ;
SILBER, S ;
POHOST, GM .
CIRCULATION, 1990, 81 (01) :289-296
[3]   FEASIBILITY OF TOMOGRAPHIC TC-99M-HEXAKIS-2-METHOXY-2-METHYLPROPYL-ISONITRILE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL AREA AT RISK AND THE EFFECT OF TREATMENT IN ACUTE MYOCARDIAL-INFARCTION [J].
GIBBONS, RJ ;
VERANI, MS ;
BEHRENBECK, T ;
PELLIKKA, PA ;
OCONNOR, MK ;
MAHMARIAN, JJ ;
CHESEBRO, JH ;
WACKERS, FJ .
CIRCULATION, 1989, 80 (05) :1277-1286
[4]   MYOCARDIAL KINETICS OF TC-MIBI IN CANINE MYOCARDIUM AFTER DIPYRIDAMOLE [J].
GLOVER, DK ;
OKADA, RD .
CIRCULATION, 1990, 81 (02) :628-637
[5]   COMPARISON OF THE MYOCARDIAL UPTAKE OF A TECHNETIUM-LABELED ISONITRILE ANALOG AND THALLIUM [J].
LEPPO, JA ;
MEERDINK, DJ .
CIRCULATION RESEARCH, 1989, 65 (03) :632-639
[6]  
LEPPO JA, 1990, J NUCL MED, V31, P67
[7]  
LI QS, 1990, J NUCL MED, V31, P1069
[8]   TC-99M HEXAKIS 2-METHOXY-2-ISOBUTYL ISONITRILE AND TL-201 EXTRACTION, WASHOUT, AND RETENTION AT VARYING CORONARY FLOW-RATES IN RABBIT HEART [J].
MARSHALL, RC ;
LEIDHOLDT, EM ;
ZHANG, DY ;
BARNETT, CA .
CIRCULATION, 1990, 82 (03) :998-1007
[9]  
MAUBLANT JC, 1988, J NUCL MED, V29, P48
[10]   UPTAKE AND RELEASE OF 2 NEW TC-99M LABELED MYOCARDIAL BLOOD-FLOW IMAGING AGENTS IN CULTURED CARDIAC-CELLS [J].
MAUBLANT, JC ;
MOINS, N ;
GACHON, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (04) :180-182