QUANTITATIVE STUDY OF THE SUSCEPTIBILITY DIFFERENCE BETWEEN TRABECULAR BONE AND BONE-MARROW - COMPUTER-SIMULATIONS

被引:53
作者
MAJUMDAR, S
机构
[1] Department of Radiology, University of California, San Francisco, California
关键词
D O I
10.1002/mrm.1910220111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Inherent differences in tissue magnetic susceptibility produce inhomogeneities in the static magnetic field which give rise to an additional dephasing of the transverse magnetization in gradient‐echo images. The enhanced dephasing of the signal results in an increase of the apparent relaxation rate 1/T 2* and a corresponding decrease in signal intensity. These effects have been used to explain the regional loss of marrow signal intensity in the appendicular skeleton, where in the presence of trabecular bone in the proximal tibia there is an enhanced loss of signal compared to the tibial shaft where there is no trabeculation. It has been postulated that differences in tissue magnetic susceptibility arising due to the marrow‐trabeculae interface give rise to magnetic field inhomogeneities and a reduced T 2*. In this study computer simulations are used to determine whether susceptibility differences comparable to that between trabecular bone and tissue relate to the reduction of tissue T 2* and whether the reduction in T 2* is also related to the concentration and magnitude of susceptibility differences. In addition the effects of the spatial distribution of these particulate discontinuities in susceptibility on the measured relaxation time T 2* are also estimated. This model demonstrates that 1/T 2* increases as the number density and magnitude of such susceptibility differences increase. In a pixel of linear dimension L consisting of material simulating tissue water, the presence of circular point susceptibility differences of dimension 0.001 L with magnetic susceptibility equivalent to trabecular bone, 1/T 2*, increases at a rate of 1.60 × 10−2 s−1 /N for N ranging from 25–2500. Differences in magnetic susceptibility that are less than that between soft tissue and trabecular bone are also modeled and the simulations demonstrate that differences in magnetic susceptibility, much lower than that between trabecular bone and tissue equivalent interfaces, also produce a relaxation rate enhancement in gradient‐echo images. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:101 / 110
页数:10
相关论文
共 10 条
[1]   A MATHEMATICAL-MODEL OF DIAMAGNETIC LINE BROADENING IN LUNG-TISSUE AND SIMILAR HETEROGENEOUS SYSTEMS - CALCULATIONS AND MEASUREMENTS [J].
CASE, TA ;
DURNEY, CH ;
AILION, DC ;
CUTILLO, AG ;
MORRIS, AH .
JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (02) :304-314
[2]   INTERPRETATION OF WATER NUCLEAR MAGNETIC-RESONANCE RELAXATION-TIMES IN HETEROGENEOUS SYSTEMS [J].
GLASEL, JA ;
LEE, KH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1974, 96 (04) :970-978
[3]  
HAZLEWOOD CA, 1984, BIOPHYS J, V14, P583
[4]   STUDIES OF DIFFUSION IN RANDOM-FIELDS PRODUCED BY VARIATIONS IN SUSCEPTIBILITY [J].
MAJUMDAR, S ;
GORE, JC .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :41-55
[5]   QUANTITATION OF THE SUSCEPTIBILITY DIFFERENCE BETWEEN TRABECULAR BONE AND BONE-MARROW - EXPERIMENTAL STUDIES [J].
MAJUMDAR, S ;
THOMASSON, D ;
SHIMAKAWA, A ;
GENANT, HK .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (01) :111-127
[6]  
MANSFIELD P, 1982, NMR IMAGING BIOMEDIC, P41
[7]   EFFECT OF TRABECULAR BONE ON THE APPEARANCE OF MARROW IN GRADIENT-ECHO IMAGING OF THE APPENDICULAR SKELETON [J].
SEBAG, GH ;
MOORE, SG .
RADIOLOGY, 1990, 174 (03) :855-859
[8]  
WEHRLI FW, 1909, 8TH P ANN M SMRM, V1, P217
[9]   SUSCEPTIBILITY INDUCED MR LINE BROADENING - APPLICATIONS TO BRAIN IRON MAPPING [J].
WISMER, GL ;
BUXTON, RB ;
ROSEN, BR ;
FISEL, CR ;
OOT, RF ;
BRADY, TJ ;
DAVIS, KR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) :259-265
[10]  
1973, CRC HDB CHEM PHYSICS, pE109