OPTIMUM POSITION FOR AN ANTISIPHON DEVICE IN A CEREBROSPINAL-FLUID SHUNT SYSTEM

被引:27
作者
TOKORO, K
CHIBA, Y
机构
[1] Department of Neurosurgery, Kanagawa Rehabilitation Center, Kanagawa-ken 243-01, 516 Nanasawa, Atsugi-shi
关键词
ANTISIPHON DEVICE; HYDROCEPHALUS; RADIONUCLIDE SHUNTOGRAPHY; SHUNT FLOW; VENTRICULOPERITONEAL SHUNT;
D O I
10.1227/00006123-199110000-00006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The effects on shunt flow from the position of an antisiphon device (ASD) and from changes in posture in hydrocephalic patients were examined. Fifty patients with hydrocephalus (including 36 with normal pressure hydrocephalus) were investigated, using quantitative radionuclide shuntography (99mtechnetium-pertechnetate) in the supine, sitting, and standing positions. The types of shunt valve used were as follows: Mishler dual chamber low pressure without ASD (16 cases), with ASD 40 cm below the level of the foramen of Monro (three cases), and with ASD 10 cm below the level of the foramen of Monro (12 cases); low pressure with integral ASD (14 cases); and medium pressure with integral ASD (five cases). In patients with a low pressure valve without ASD, shunt flow was least in the supine position (0.0011 ml/min) but increased significantly in the sitting position (0.4381 ml/min, P < 0.001) because of the siphon effect. Conversely, in patients with a low pressure valve with integral ASD, shunt flow was maximal in the supine position (0.1056 ml/min) and decreased significantly in the sitting position (0.0017 ml/min, P < 0.001), indicating overfunction of the ASD. Intracranial pressure (ICP) in the supine position increased significantly compared with patients with a low pressure valve without ASD (93.6 and 20.7 mm H2O, respectively, P < 0.01). Intermediate values for shunt flow in the supine and sitting positions (0.0279 and 0.0896 ml/min, respectively) and for ICP (55.8 mm H2O) were obtained with patients with a low pressure valve with the ASD 10 cm below the level of the foramen of Monro (P < 0.05). Shunt flow in the supine position correlated negatively with the log of the shunt flow in the sitting position (P < 0.025). Shunt flow in the sitting position correlated positively with the distance between the ASD and the level of the foramen of Monro (P < 0.01). ICP in the supine position correlated negatively with the distance between the ASD and the level of the foramen of Monro (P < 0.025). Shunt flow and ICP are significantly affected by the position of the ASD and the patient's posture. The optimum position for the ASD appears to be 10 cm downstream; the resulting hydrostatic column helps initiate flow when the patient assumes the sitting and standing positions.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 23 条
[1]   THE RELATIONSHIP BETWEEN VENTRICULAR FLUID PRESSURE AND BODY POSITION IN NORMAL SUBJECTS AND SUBJECTS WITH SHUNTS - A TELEMETRIC STUDY [J].
CHAPMAN, PH ;
COSMAN, ER ;
ARNOLD, MA .
NEUROSURGERY, 1990, 26 (02) :181-189
[2]  
CHERVU S, 1984, J NUCL MED, V25, P91
[3]   VENTRICULOJUGULAR SHUNT AGAINST THE DIRECTION OF BLOOD-FLOW .3. OPERATIVE TECHNIQUE AND RESULTS [J].
ELSHAFEI, IL .
CHILDS NERVOUS SYSTEM, 1987, 3 (06) :342-349
[4]   VENTRICULOJUGULAR SHUNT AGAINST THE DIRECTION OF BLOOD-FLOW .2. THEORETICAL AND EXPERIMENTAL BASIS FOR SHUNTING THE CEREBROSPINAL-FLUID AGAINST THE DIRECTION OF BLOOD-FLOW [J].
ELSHAFEI, IL ;
ELRIFAII, MA .
CHILDS NERVOUS SYSTEM, 1987, 3 (05) :285-291
[5]   SYMPTOMATIC LOW INTRACRANIAL-PRESSURE IN SHUNTED HYDROCEPHALUS [J].
FOLTZ, EL ;
BLANKS, JP .
JOURNAL OF NEUROSURGERY, 1988, 68 (03) :401-408
[6]   EFFECT OF CEREBROSPINAL-FLUID SHUNTS ON INTRACRANIAL PRESSURE AND ON CEREBROSPINAL-FLUID DYNAMICS .2. NEW TECHNIQUE OF PRESSURE MEASUREMENTS - RESULTS AND CONCEPTS .3. CONCEPT OF HYDROCEPHALUS [J].
FOX, JL ;
MCCULLOUGH, DC ;
GREEN, RC .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1973, 36 (02) :302-312
[7]   EXPERIENCES WITH THE ANTI-SIPHON DEVICE (ASD) IN SHUNT THERAPY OF PEDIATRIC HYDROCEPHALUS [J].
GRUBER, R ;
JENNY, P ;
HERZOG, B .
JOURNAL OF NEUROSURGERY, 1984, 61 (01) :156-162
[8]   QUANTITATION OF CEREBROSPINAL-FLUID SHUNT FLOW [J].
HARBERT, J ;
HADDAD, D ;
MCCULLOUGH, D .
RADIOLOGY, 1974, 112 (02) :379-387
[9]  
HOLTER JW, 1985, J NEUROSURG, V62, P791
[10]   FLUID-FLOW PERFORMANCE OF A NEW SIPHON-CONTROL DEVICE FOR VENTRICULAR SHUNTS [J].
HORTON, D ;
POLLAY, M .
JOURNAL OF NEUROSURGERY, 1990, 72 (06) :926-932